62 Ferm
SAFETY AND OPERATING
INSTRUCTIONS
High pressure cleaner FHPW-250
THE NUMBERS IN THE FOLLOWING TEXT
CORRESPOND WITH THE PICTURES AT PAGE 2.
Always read the instruction for electrical products
carefully before use. It will help you understand
your product more easily and avoid unnecessary risks.Keep
this instruction manual in a safe place for future use.
CONTENTS:
1. Machine data
2. Safety instructions
3. Assembly
4. Use
5. Service & maintenance
1. MACHINE DATA
INTRODUCTION
The high pressure cleaner FHPW-250 is quick and
efficient for cleaning vehicles, machines, boats, buildings,
etc., by the removal of stubborn dirt using clean water
and chemical detergents.When using chemical
detergents, only use biodegradable types.
Only clean vehicle engines in areas in which suitable oil
traps are installed.
TECHNICAL SPECIFICATION
CONTENTS OF PACKING
High pressure cleaner
Hose
Trigger
Lance holder
Hose handle
Lance extension
Lance adjustable nozzle
Detergent spray attachment
Safety and operating instructions
Warranty card
FEATURES
Fig. 1
1. Water outlet
2. Water inlet with filter
3. Main switch
4. Adjustable spray nozzle
5. Lance extension
6. Trigger with lock mechanism
7. High pressure hose
8. Detergent spray attachment
9. Lance holder
10. Hose handle
2. SAFETY INSTRUCTIONS
EXPLANATION OF SYMBOLS
In this manual and/or on the machine the following
symbols are used:
Read instructions carefully
In accordance with essential applicable safety
standards of European directives
Denotes risk of personal injury, loss of life or
damage to the tool in case of non-observance of
the instructions in this manual.
Indicates electrical shock hazard.
Immediately unplug the plug from the mains
electricity in the case that the cord gets damaged
and during maintenance
Faulty and/or discarded electrical or electronic
apparatus have to be collected at the appropriate
recycling locations.
DO NOT direct the water jet towards
people or animals.DO NOT direct the
water jet towards the unit itself, electrical
parts or towards other electrical
SAFETY INSTRUCTIONS
When using electric machines always observe the safety
regulations applicable in your country to reduce the risk
of fire, electric shock and personal injury. Read the
following safety instructions and also the enclosed safety
instructions.
Keep these instructions in a safe place!
ELECTRICAL SAFETY
Always check if your mains voltage corresponds with
the value on the type plate.
When replacing old cables or plugs:
Throw away old cables or plugs immediately as soon
as new ones have replaced these. It is dangerous to
put the plug of a loose cable into the socket outlet.
When using extension cables:
Only use an approved extension cable that is suitable
Model | FHPW-250
Art. nr. | GRM1008
Voltage | AC 230 V
Input power | 1900 W
Working pressure | 110 bar
Max. working pressure | 200 bar
Max. water temperature | 50º C
Working flow rate | 6.01 l/min
Hose length | 5 m
Weight | 16 Kg
Dimensions | 52 x 52 x 36 cm
Lpa (sound pressure level) | 83.5 dB (A)
Vibration level | 1.0 m/s
2
Ferm 3
SPARE PARTS LIST FHPW-250
REF NR DESCRIPTION POSITION
501094 FILTER 1
501096 VALVE SET 2
800035 CONDENSATOR 35UF 3
501097 MAIN SWITCH 4
501102 HOSE 5
501095 WHEEL 6
501104 HANDLE 7
501099 TRIGGER 8
501100 LANCE EXTENSION 9
501101 LANCE ADJUSTABLE NOZZLE 10
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm GRM1008 - FHPW 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm GRM1008 - FHPW 250 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 3,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info