538642
5
Zoom out
Zoom in
Previous page
1/46
Next page
OIL-FREE ELECTRIC COMPRESSOR
THE NUMBERS IN THE FOLLOWING TEXT COR-
RESPOND WITH THE PICTURES AT PAGE 2-4
TECHNICAL SPECIFICATIONS
Electric compressor
Series GMS-VS-AIRCLIK-F 1
NB: For the European market, the tanks of the com-
pressors are constructed in accordance with the Direc-
tive CE87/404.
For the European market, the compressors are con-
structed in accordance with the Directive CE98/37.
Sound level, measured in open area at a distance of 1 m
±3dB (A) at the maximum service pressure, see table 1.
F
CV/kW RPM dB(A)
1/0.75 1450-1750 65
1.5/1.1 2850 77
1.5/1.1 3450 80
2/1.5 2850 78
GMS
CV/kW RPM dB(A)
0.75/0.55 1450-1750 77
1.5/1.1 1450-1750 77
1.5/1.1 2850 78
VS
CV/kW RPM dB(A)
2/1.5 1450 77
2/1.5 1750 80
3/2.2 2850 82
Table 1 - Sound levels of the compressors
The sound level can increase from 1 to 10 dB(A), depen-
ding on the location where the compressor is installed.
SAFETY INSTRUCTIONS
The following symbols are used in this manual:
Denotes the risk of possible personal injury, loss of
life or damage to the machine if the instructions in
this manual are not observed.
Indicates electric tension.
Read this manual carefully before putting the machine
into use. Make sure that you know how the machine
functions and how to operate it. Maintain the machine in
accordance with the instructions to make sure that it
always functions properly. Keep this manual and the
enclosed documentation with the machine.
Most accidents during use of the compressor are due to
negligence of the basic safety regulations.
By recognizing potentially dangerous situations timely
and observing the safety regulations, accidents can be
avoided.
The basic safety regulations are listed in the section
"SPECIAL SAFETY INSTRUCTIONS" of this manual, as
well as in the section about using and maintaining the
compressor.
The dangerous situations to be avoided in order to pre-
vent all risks of serious injuries or damage to the machine
are indicated by warnings on the compressor or in the
manual.
Never use the compressor in the wrong way, but only as
recommended by the designer, unless you are comple-
tely sure that there is no danger, neither for the user nor
for the people in the vicinity.
SPECIAL SAFETY REGULATIONS
Attention! Wrong use and poor maintenance of
the compressor can harm the user physically. To
avoid these risks, you are requested to pay attention to the fol-
lowing instructions:
1. Do not touch the moving parts
Never put your hands, fingers or other body parts
near the compressor’s moving parts.
2. Never use the compressor without the pro-
tections installed
Never use the compressor without all the protec-
tions installed in the correct position (e.g. fairings,
chain protection, safety valve). If you must remove
these protections for maintenance or operation,
make sure that the protections are properly moun-
ted in their original positions before using the com-
pressor again.
3. Always wear safety glasses
Always wear safety glasses or protections for the
eyes of the same quality.
Do not point the compressed air at any part of your
or someone else’s body.
Max. operating pressure | 8 bar
Max. service pressure | 8 bar
UK
English
Ferm 588 Ferm
ONDERDELENLIJST TYPE FX
REF NR DESCRIPTION FERM NR
1 TANK
2 AFVOER CONDENSWATER
3 WIEL
4 BESCHERMINGSSTROOMLIJNKAP
5 LUCHTFILTER
6 DRUKREGELAAR
7 DRUKREDUCTIEMACHINE
8 UITGANG SAMENGEPERSTE
9 MANOMETER
10 HANDVAT
ONDERDELENLIJST TYPE F 1
REF NR DESCRIPTION FERM NR
1 BESCHERMINGSSTROOMLIJNKAP
2 LUCHTFILTER
3 DRUKREDUCTIEMACHINE
ONDERDELENLIJST TYPE ECU
REF NR DESCRIPTION FERM NR
1 TANK
2 AFVOER CONDENSWATER
3 BESCHERMINGSSTROOMLIJNKAP
4 VEILIGHEIDSKLEP
5 LUCHTFILTER
6 DRUKREDUCTIEMACHINE
7 UITGANG SAMENGEPERSTE LUCHT
8 DRUKREGELAAR
9 MANOMETER
ONDERDELENLIJST TYPE F
REF NR DESCRIPTION FERM NR
1 BESCHERMINGSSTROOMLIJNKAP
2 LUCHTFILTER
3 DRUKREDUCTIEMACHINE
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1012 FC-700F - 242650 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1012 FC-700F - 242650 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info