513634
4
Zoom out
Zoom in
Previous page
1/78
Next page
4 GB
Operation / Tips for the best cooling ... / Exchanging the 12 V fuse / Possible malfunctions / Cleaning and care / Warranty
avoids temperature control by means of the constant on / off switching of tra-
ditional refrigeration technology, which causes a high level of material wear.
If you wish to achieve a colder inside temperature in the coolbox, briefly
press the ‘boost switch’ (the blue LED lights up if the the ‘boost function’ is
switched on). By doing this, you exit the ‘eco function’ (normal operation)
and the power supply is automatically switched to the maximum cooling
output. Since with thermoelectric coolboxes the refrigeration temperature is
always dependent on the ambient temperature around the coolbox, the cool-
ing unit always produces an inside temperature when the ‘boost function’ is
switched on, which is up to 18 °C lower than the particular outside tempera-
ture of the coolbox (example: outside temperature 24 °C = inside temperature
approx. 6 °C). Please be aware that – during the ‘boost function’ – freezing
of the coolbox contents can occur at low outside temperatures.
The ‘boost function’ is set at the factory in such a way that after 24 hours
operation it automatically switches to the power-saving normal operation
(= automatic inside temperature between 8 °C and 14 °C). To switch the ‘boost
function’ off earlier, press the ‘boost switch’ again (the blue LED goes out).
Function with 12 V operation
Please note:
When the coolbox is operating with a 12 V power supply, the cooling unit
always produces a temperature difference from the ambient temperature of
up to 18 °C. The ‘boost switch’ only functions in 230 volt operation; with
12 volt operation the ‘boost switch’ does not display any function!
Tips for the best cooling
output and energy saving
Select a well ventilated location protected from sunshine.
Only place pre-cooled contents into the coolbox.
Do not open the coolbox longer than necessary.
Don’t leave the lid open longer than necessary.
Ensure that the coolbox is not packed too full and that the air can
circulate adequately between the coolbox contents.
In order that a high level of energy saving can be achieved, normal op-
eration (no ‘boost function’) is recommended for longer periods of use in
230 V operation.
Exchanging the 12 V fuse
To exchange the fuse
6
, first remove the red adapter
3
from the plug.
Unscrew the screw
1
with a suitable Phillips screwdriver from the top
half of the housing
2
.
Lift the top half of the housing from the bottom half
5
.
Note: Hold the contact spring tightly
4
while you remove the fuse.
Otherwise the contact spring can jump out.
Lift the contact pin
7
carefully out of the housing section. The fuse can
now be removed.
Note: if the thin metal connection in the middle between the two metal
caps is broken, then the fuse is defective and must be replaced.
Press the contact spring backwards and insert the new fuse carefully into
the groove provided for it. Now place the rear edge of the contact pin
on the front metal cap of the fuse. By releasing the contact spring, the
fuse and contact pin are located in the groove.
Screw the top and bottom halves of the housing together again, place
the red adapter
3
back on and tighten this again. The plug is now
ready for operation.
3
12
7
6
46 5
Possible malfunctions
Firstly check whether you have correctly followed the instructions for using the
coolbox, then also check:
Is the connection cable correctly connected and does your car cigarette
lighter / domestic socket function properly?
Have you set up the coolbox in such a way that the air can circulate
freely and that venting of the cooling unit can occur?
Is the fuse in the plug of the 12 V connection cable OK?
If you can not rectify the malfunction on your own, please contact our
Customer Service (see chapter on “Service centre”).
Cleaning and care
Do not use any abrasive cleaning agents. If you do, there is a risk of
damage to the product.
Before any cleaning, pull the plug of the connection cable out of the
socket or of the cigarette lighter. Otherwise there is a risk of electric
shock.
Never clean the coolbox under running water. If you do, this could result
in damage to the electrics.
Before cleaning, remove the electrical lid by pulling it out at a slight angle
from the right rear recess.
Use a dry cloth for cleaning the electrical lid.
Use a damp cloth and a mild soap solution for cleaning the bottom
section of the coolbox.
Use clean water to rinse off those parts cleaned with soapy water.
Warranty
The warranty for this appliance is for 2 years from the date of purchase.
Where there are defects in this appliance, you have statutory rights available
against the seller of the appliance. Your statutory rights are not restricted in
any way by our warranty as detailed below.
Warranty conditions:
The warranty period begins on the date of purchase. Please retain the original
receipt safely. This receipt is required as proof of purchase.
Should this appliance show any fault in materials or manufacture within 2 years
from date of purchase, it will be repaired or replaced – at our choice – by us
free of charge. This warranty is conditional on the defective appliance and
the receipt of purchase being presented within the 2 year warranty period,
and that there is a brief written description of the nature of the defect and of
the date it arose.
If the defect is covered by our warranty, you will receive the repaired appli-
ance back or a new appliance. A new warranty period does not commence
with the repair or with the exchange of the appliance.
4


Need help? Post your question in this forum.

Forumrules
1

Forum

ezetil-e40

Reset search

  • Cooler operates fine when plugged in inside. Will not work when plugged into vehicle Submitted on 11-10-2022 at 16:11

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ezetil E40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ezetil E40 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info