ATTENTION!
This contains information, which must be strictly
observed to avoid damage to the door
3
Where ‘left’ and ‘right’ hands are specified, the door
is always viewed from inside the garage looking out-
wards.
These instructions show right hand side parts.
The manufacturer shall not be held liable for damage
or operational faults due to non-compliance with these
installation instructions. For safety, unauthorised
modification or alterations of this door are not permit-
ted. Modification of this door, its operational parts or
GENERAL & INTRODUCTION
DOOR VARIATIONS
This sectional door is supplied with one of two dif-
ferent balancing systems. Most installation steps shown
in these instructions cover these two systems. Where the
steps differ for each balancing system, symbols are shown
to guide you to follow the system supplied with your door.
Please take a minute to familiarise yourself with the sym-
bols (shown below). The clearances required for installa-
tion are also shown.
When installing an electric operator to this door, always
consult the installation instructions supplied with the ope-
rator.
INSTALLATION CLEARANCES REQUIRED FOR EACH BALANCING SYSTEM
*When B = 1900 mm add 100 mm to the depth shown
the attachment of additional door weight will lead
to invalidation of the door guarantee.
The installation of a garage door requires technical
knowledge and skills. The manufacturer shall not be
held liable for any damages or injuries incurred
during installation. If you are in any doubt about
your ability to install this door correctly and safely,
contact a qualified tradesperson.
Prior to installation, this garage door must be stored in a
dry, sheltered place, protected from risk of damage and /
or loss of components.
STORAGE
The fixings supplied with this door are for use in general
brickwork, walls, ceiling, timber, steel and concrete. If
this door is to be installed to any other material or if the
structure is of poor quality, it is the responsibility of the
installer to use suitable, good quality, fixing items. These
are readily available through trade outlets. It is important
to use plugs and fastening screws with washers that are
suitable for the type of masonry involved, with a minimum
screw diameter of 8 mm. An option kit of installation
brackets can be used to fix the wall tracks (require extra
side room 40 mm).
SAFETY
Ensure that the springs of the torsion spring unit are not
damaged during transit, storage or installation.
Important instructions and notes are highlighted as
follows:
They identify operations and information, which must be
strictly observed and followed to avoid endangering per-
sons or damage to the door.
This identifies operations, which must be
strictly observed to avoid endangering
persons.
CAUTION
For your safety, please read these instructions
thoroughly and ensure you understand them
before starting the installation.
These installation instructions are supplied together
with an illustration plan. Please keep both together in
a safe place for future reference .
!
!
Clearances Required
Side
room
Headroom
Manual
Depth*
Manual
Headroom
El-operated
Depth
El-operated
80 150 B+700 150 B< 2250 = 3445
Tension (low headroom) (TEL)
Torsion (front) (TOF)
80 200 B+700 200 B< 2250 = 3445
B> 2375 = 4450
Torsion (rear) (TOR)
80 100 B+800 120 B< 2250 = 3445
B> 2375 = 4450
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Entrematic Superior 42 TOF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Entrematic Superior 42 TOF in the language / languages: All languages as an attachment in your email.

The manual is 4,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info