INTRODUCTION
The code lock AG40KE11B is designed for use in combinaon with the Home Alarm System AG400011. By using
a 4-digit access code you can turn the alarm system armed, parally armed and disarmed. In addion, a panic
alarm can be acvated.
Transmission
Low Baery
Code Confirmaon
Arm
Disarm
PARM1
PARM2
INSERTING THE BATTERY
To insert the baery, first remove the mounng plate by unscrewing the (a) screw on the boom of the unit.
Next, unscrew the two screws of the baery plate (b) on the back of the unit. Then insert the included 9-volt
baery (c) in the compartment and screw the baery plate back on.
MOUNTING PLATE
Use the mounng plate you unscrewed in the previous step as a
template to mark the drill holes on the wall. Aer drilling the holes,
fix the mounng plate to the wall with the included wall plugs and
screws. When you have completed configuraon, you can place the
keypad back in the mounng plate and screw it back in with the
screw (a) on the boom.
ADDING THE WIRELESS KEYPAD TO THE HOME ALARM SYSTEM AG4000
1. On the alarm panel, enter the alarm panel’s PIN (1234 by default) + DISARM to disarm the system.
2. Enter PIN (1234 by default) + 15 + PARM to start the binding process. The DISARM LED will start to
blink for 30 seconds with a beep tone. Within 30 seconds, set the remote keypad to enter binding mode by
using the tamper switch (d) on the back.
3. If the remote keypad is added successfully, the DISARM LED will turn on for 1 second along with a long
beep sound. If the binding process fails, it will meout aer 30 seconds and 3 short beeps will be heard. To
exit the binding process, press the DISARM key on the alarm panel.
CHANGING THE ACCESS CODE
For security, it is highly recommended that you change the standard PIN (1234) to a four-digit PIN of your own
choosing. The system can support one master user code, and five user access codes.
* To set a new master access code take the following steps
1. Press followed by the standard PIN (1234) and again .
The LED will now light up and flash three mes.
2. Choose a new four-digit PIN and enter this now, followed by . The LED will now light up and
flash four mes to confirm. The master access code has now been changed.
* To set user access codes, take the following steps
1. Press followed by the master access code you have set in the previous step and then again .
The LED will now light up and flash three mes.
2. Enter (for user code 1) followed by and then the four-digit user access code you wish to set,
followed by . The LED will now light up and flash four mes.
3. To set user access codes 2-5, simply repeat the above steps but replace the with a number 2-5.
Note: The user access codes will only apply to the remote keypad. When operang the home alarm system from
the main alarm panel, you will sll need to use the PIN you have set for that.
TESTING THE REMOTE KEYPAD
To fully arm the system: Enter [your access code] followed by
Parally arm the system: Enter [your access code] followed by or
To disarm the system: Enter [your access code] followed by
Your buon presses will be confirmed by the lighng up. It is important you also confirm the
transmission of the code once you have finished entering the command by seeing if the is flashing. When
first seng up the system, we recommend you test it near the main alarm panel so that you can confirm the
keypad successfully transmied by seeing the alarm mode change on the alarm panel and hearing a beep tone.
PANIC SIGNAL
The remote keypad allows you to send a panic signal, for instance because you are using the remote keypad
under duress. To send a panic signal, press and hold the and at the same me for at least two
seconds and unl the LED is flashing rapidly.
DISABLING THE REMOTE KEYPAD
If a sequence of more than 16 incorrect key presses is entered, the keypad will be disabled for 1 minute. If the
keypad is consecuvely disabled 3 mes, the keypad will send a tamper signal to the alarm panel and the
LED will flash slowly.
Note: When the keypad is disabled for 1 minute, the LED will flash slowly, indicang that the Keypad is
temporarily shut down. During this minute, any key presses will be treated as an invalid input. Aer 1 minute
has elapsed, correct input will be accepted again.
2
2
2
1
1
1
1
1
1
(a)
(b)
(c)
UP
(a)
Tamper
switch
(d)
-1- -2-
2
1
1
2
3
4
5
6
7
8 9
0
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elro AG40KE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elro AG40KE in the language / languages: English as an attachment in your email.

The manual is 2,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elro AG40KE

Elro AG40KE User Manual - German - 2 pages

Elro AG40KE User Manual - Dutch - 2 pages

Elro AG40KE User Manual - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info