741419
3
Zoom out
Zoom in
Previous page
1/8
Next page
ENGLISH
IR600
INFRARED DETECTOR
1. Test/Learn button and LED indicator
The Test button is used to test wireless
communication performance and to carry out the
learning procedure of the device by the control unit.
The LED indicator, it is used to indicate the system
state.
2. Battery isolator
3. Pulse counter/sensitivity up jumper (JP3)
4. Tamper switch
Coverage diagram
LED
In normal operating mode, the LED indicator blinks to indicate that signals are being transmitted in the following situations:
When movement is detected in flat battery conditions.
When the cover is opened and the tamper switch is actuated.
When movement detected if the tamper alarm condition persists.
When motion is detected in Test mode.
When the Test button is pressed in tamper alarm conditions or if the battery of the detector is flat.
The LED does not blink if the tamper switch and the battery detector are normal and not in Test mode.
The LED blinks rapidly twice to confirm reception by the control unit.
Jumper
If the jumper is set to OFF (if the jumper connection is removed or positioned on only one pin), the detection sensitivity is
at normal level (default).
If the jumper is set to ON, the detection sensitivity of the detector is maximum.
Tamper
The tamper switch protects the detector from unauthorised opening of the cover.
Test mode
The detector can be set to Test mode by pressing the Test button on the front cover for a few seconds. In Test mode the sleep
time will be deactivated and the LED indicator will blink whenever motion is detected. Whenever the Test button is pressed, the
detector transmits a test signal to the control unit to test the wireless communication range and goes to Test mode for 3 minutes.
It automatically exits Test mode after 3 minutes and goes back to normal mode.
SLEEP TIME
time between the detection of a movement and the next movement
Learning procedure
Extract the battery isolator to activate the battery.
The LED will blink for 30 seconds (the detector is being initialised). During initialisation, the detector will not be
activated. It is advisable not to generate any alarms during this time. Once the initialisation time has finished, the LED
will switch off and the detector is ready to start working.
Enable the control unit to run the device learning procedure. Refer to the control unit instruction manual for details.
Hold the Test button on the front cover pressed.
Refer to the instruction manual of the control unit to complete the learning process.
After having integrated the detector, set the control unit to Walk Testmode: keep the detector in the required position
and press the Test button to confirm that the concerned position is within the communication range of the control unit;
see the instruction manual of the control unit to complete the learning procedure.
Proceed with the installation after having ascertained that the detector is working in the desired position.
QUICK GUIDE
DS80IR2E-002A
Installation
height
Infrared range
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elkron IR600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elkron IR600 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 0,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elkron IR600

Elkron IR600 User Manual - English, German, French, Italian - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info