Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a bi-polar switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation
instructions.
Warning: Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Mounting
Before beginning installation:
Check that the product purchased is of a suitable size for
the chosen installation area.
To facilitate installation, remove the fat filters and the
other parts allowed and described here, dismantle and
mount it.
To remove see also the relative paragraphs.
Remove the active carbon (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall/ceiling. Otherwise put a thick, protective
covering over countertop, cooktop or range to protect
from damage and debris. Select a flat surface for
assembling the unit. Cover that surface with a protective
covering and place all canopy hood parts and hardware
in it.
Disconnect the hood during electrical connection, by
turning the home mains switch off.
In addition check whether near the installation area of the
hood (in the area accessible also with the hood mounted)
an electric socket is available and it is possible to
connect a fumes discharge device to the outside (only
suction version).
Carry out all the masonry work necessary (e.g.
installation of an electric socket and/or a hole for the
passage of the discharge tube).
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
Fig. 5
1. Adjust extension of the hood support structure, as the
final height of the hood depends on this.
Note: In some cases the upper section of the lattice is
fixed to the lower section with one or more screws,
eventually check and remove them temporarily to allow
the adjustment of the support structure.
2. Fix the two sections of the structure with a total of 16
screws (four per corner).
Note: If envisaged, insert the reinforcement bracket in
the lattice and put it on top of the motor unit.
The bracket should be fixed in place again only after the
perforated frame has been fitted to the ceiling.
Fig. 6
3. Apply the drilling template to the ceiling vertically over the
cooking top (the centre of the template should
correspond to the centre of the cooking top and the sides
should be parallel to the sides of the cooking top – the
side of the template with the word FRONT (or with the
arrows) corresponds to the control panel side). Connect
the electricity.
4. Drill as shown (6 holes for 6 wall plugs – 4 plugs for
fixture), screw the outer screws leaving a space of about
1 cm. between the screw head and the ceiling.
Fig. 7-8
5. Fit 150mm exhaust pipe inside the truss and connect it
to the motor compartment connection ring.
(exhaust pipe and fixing brackets are not supplied).
For filter versions (5F), fit deflector F to the truss and
secure it to the bracket supplied using 4 screws, then
connect the exhaust pipe to the connection ring located
on the deflector.
Fig. 9
6. Hook the frame onto the 4 screws (see step 4).
CAUTION! The side of the truss with connection box
corresponds to the side of the control panel with hood
assembled.
7. Tighten the 4 screws.
8. Insert and tighten another 2 screws in the remaining free
holes for secure fixing.
Note - only for the suction Version: connect the upper
end of the discharge tube to the discharge device toward
the exterior (e.g. hole in the ceiling).
9. Fix the reinforcement bracket (see operation 2) to the
lattice in as intermediate a position as possible.
Carry out the electrical connection to the mains power supply,
only turn on the power supply upon completion of assembly.
Fig. 10
10. Secure the hood to the truss using 8 screws.
CAUTION! The side of the truss with connection box
corresponds to the side of the control panel with hood
assembled.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elica Meridiana at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elica Meridiana in the language / languages: English as an attachment in your email.

The manual is 3,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info