Wireless Gas Leak Detector
(Model EL-2762)
Introduction
Electronics Line Ltd's Wireless Gas Leak Detector detects
mixtures of air and combustible gases (Natural Gas, Methane,
Propane and Butane).
Upon detecting the presence of gas, the unit emits an alarm and
notifies the control panel.
The main features of your Wireless Gas Leak Detector include the
following:
Integrated transmitter designed for use EL's wireless alarm
systems
Easy to install
Monitoring for Natural Gas, Methane, Propane and Butane in
a continuous manner
Loud alarm (85 dB) when detecting a buildup of Gas
Test button
Self-test
Selecting the installation location
The Wireless Gas Leak Detector will function effectively if installed in the
correct location. Consider the following before mounting the gas alarm:
Methane (Natural) Gas: Methane is lighter than air,
therefore the greatest concentration of gas is found right
below the ceiling, and therefore the Wireless Gas Leak
Detector should be installed on the wall, approximately 30
cm (12”) below the ceiling.
Butane Gas: Propane and Butane are heavier than air,
therefore the greatest concentration of gas is found right
above the floor level. The Wireless Gas Leak Detector
should therefore be installed about 30cm (12”) above the
floor. Do not mount in a location where the gas alarm
could be damaged by dirt, liquids, etc.
Note:
Do not install the detector on the ceiling or on the floor.
Floor
Ceiling
30 cm (12")
30 cm (12")
Detector location for Methane (Natural) Gas detection
Detector location for Propane and Butane detection
Install the detector in close proximity to every
gas-operated appliance.
Do not:
Install the gas detector directly on any gas appliance.
Install the gas detector in sealed or closed compartments or
in an area where a wall or a closed door can obstructs the
flow of gas to the gas alarm.
Install the gas detector in locations where fans, open doors,
open windows etc. may prevent gas from reaching the
sensor.
Install the gas detector in any room where aerosols or
ammonia are used (e.g. bathrooms).
To install the detector:
1. Remove the mounting bracket from your unit according to Fig. 1.
1 2 3
Fig. 1
2. Hold the Mounting bracket against the wall as a template and
mark the locations for the 2 mounting holes.
3. Using a 3/16-inch (5 mm) drill bit, drill two holes at the marks
and insert wall plugs (Fig. 2).
Fig. 2
4. Secure the mounting bracket to the wall.
5. Line up the side slot of the bracket and the detector. Push the
detector onto the mounting bracket and fix it (see arrow
direction, Fig. 2). Pull the detector outwards to make sure that it
is securely attached to the mounting bracket.
6. Connect the detector power cable to the wall power outlet.
Transmitter/Receiver Communication Setup
1. Set the panel to registration mode.
2. Insert the batteries into compartment. The detector enters
registration mode during which a transmission is sent every
few seconds. You can terminate registration mode by
pressing the Test Button. Test mode is automatically
terminated after approximately five minutes.
3. Verify that the detector has been identified by the receiver.
TEST/HUSH POWER SERVICE ALARM ALARM VENT
SENSOR VENT
Fig. 3
TESTING YOUR DETECTOR
To test the detector (do not test when detector is at warm up
mode), press the Test Button.
The red and orange LED's will flash and a sound will be
heard
MUTING YOUR DETECTOR
You can partially mute the detector in an event of alarm by
pressing the Test Button. The Red LED will continue to flash and a
short beep will be heard every 16 seconds.
Formatiert: Schriftartfarbe:
Automatisch
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Electronics Line EL-2762 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Electronics Line EL-2762 in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Electronics Line EL-2762

Electronics Line EL-2762 User Manual - German - 5 pages

Electronics Line EL-2762 User Manual - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info