Operating instructions
Overview of main functions
Button
Action
Procedure
Display / Function
Set room temperature
Zone 1 and zone 2
Actuate rotary knob left/right
Turn rotary knob Confirm
with OK button or
wait 5 sec. or press
Comfort setpoint with blinking temperature
Blinking temperature in 0,5 °C steps from 10 to 30 °C
Comfort setpoint saved Comfort
setpoint cancelled
- after 3 sec. Main menu appears
Set room temperature
for zone 1 or zone 2
Zone 2 independent from zone 1
Actuate rotary knob left/right
Confirm with OK button
Actuate rotary knob left/right
Confirm with OK button or
wait 5 sec. or press
Choose heating zone
Heating zone is chosen
Blinking temperature in 0,5 °C steps from 10 to 30 °C
Comfort setpoint saved Comfort setpoint cancelled
- after 3 sec. Main menu appears
Switch on /off DHW
operation
Press button
DHW mode on / off
(see indication below DHW symbol)
- On: DHW mode by time programm
- Off: no DHW operation
- Safety functions activated
Change heating
operation mode
Factory setting
Press button 1x
Press button 1x again
Press button 1x again
Automatic mode on, with:
- Heating by time programm
- Temperature setpoint by heating programm
- Safety functions activated
- Summer/Winter automatic switching activated
- ECO-functions activated
(see indication below operation symbol)
Continuous COMFORT heating on, with:
- Heating without time programm by comfort setpoint
- Safety functions activated
Continuous REDUCED heating on, with:
- Heating without time programm by reduced setpoint
- Safety functions activated
- Summer/Winter automatic switching activated
- ECO-functions activated
Safety mode on, with:
- Heating off
- Temperature by frost protection
- Safety functions activated
Controller Stop mode
Press button > 3 sec.
Press button > 3 sec. again
304: Controller Stopp mode insert setpoint
after 3 sec. Main menu appears
Info display
Press button 1x
Press button 1x again
Press button 1x again
.....
Press button 1x
INFO Segment displayed
- Status Boiler - room temperature
- room temperature minimum
- Status DHW - room temperature maximum
- Status zone 1 - outside temperature
- Status zone 2 - outside temperature minimum
- outside temperature maximum
- Time / Date - DHW temperature 1
- Error indication - Boiler temperature
- Maintenance indication - Flow temperature
(Info display depends on configuration)
Back to main menu; INFO Segment disappears
Operation by manual
setpoint
Change factory setting
boiler temperature
Press button 1x
Press button
Press button
Turn rotary knob -/+
Press button
Press button
Press button
Manual mode on (spanner symbol appears)
- Haeting by fixed setpoint
(factory setting = 60 °C)
301: Manual mode insert setpoint?
blinking temperature set value
Status boiler
Manual mode off (spanner symbol disappears)
Deaeration
Press button > 3 sec.
Press button > 3 sec. again
312: Deaeration on
Deaeration off
Activate chimney
sweeper mode
Press button (< 3 sec.)
Press button again (< 3 sec.)
Chimney sweeper mode on
Chimney sweeper mode off
Temporary reduction of
reduced temperature on
QAA75
Press button
Press button again
Heating by reduced setpoint
Heating by comfort setpoint
RESET
Reset button
Press button (< 3 sec.)
Press button again > 3 sec.
Boiler manually blocked, no release
Boiler released, Alarm symbol disappears
7
= confirmation
= cancel, return to main menu
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Elco Thision S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Elco Thision S in the language / languages: English as an attachment in your email.

The manual is 2,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Elco Thision S

Elco Thision S User Manual - German - 20 pages

Elco Thision S User Manual - Dutch - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info