14. OVERVIEW
Indicator (LED)
Supervision mode without acoustical monitoring
Supervision mode with acoustical monitoring
Supervision mode inactive
During phone connection
Alarm independent of alarm unit state (armed or disarmed)
active on„Default value“
1)
Cause of alarm
I II III
Entry-Delay Connection mode Announcement
Emergency (Sensor-2)
2)
Delayed Hands-free connection „Emergency call activated“
Sensor-3
3)
Un-delayed Listening-in connection „Alarm due to sensor 3“
1.) Default values without en without consideration of user specific programming in accordance to section 5
2.) Emergency call activation according to section 5.2.2: An emergency call will be triggered, if the button has been
activated for one second. After a pre alarm period of 20 seconds EasyAlarm
®
starts dialling calling number(s) and a
hands-free connection is established. During the pre warning period the alarm can be cancelled by pressing the
emergency button respectively by pressing key 0 .
3.) Sensor-3 activation according to 5.3.1.
Alarms only if alarm unit is armed
active on
„Default value“
1)
Cause of alarm
I II III
Entry-Delay Connection mode Announcement
Sensor 1
4)
Un-delayed Listening-in connection Alarm due to sensor 1“
Presence verification
5)
10 Minutes/30
Seconds
Hands-free connection
“Alarm due to presence
verification”
Sensor 2
6)
Un-delayed Listening-in connection Alarm due to sensor 2“
Noise (Babyphone)
7)
Un-delayed Listening-in connection „Alarm due to noise
Mains power loss
1 Minute Hands-free connection „Alarm due to power failure “
4.) Sensor-1 activation according to 5.1.1.
5.) Sensor-1 can be used to verify if a person is present ( section 5.1.2), i.e. an alarm will be triggered if no motion is
detected within 24h. Before starting the alarm there is a pre warning period of ten minutes. If activation is detected
(motion detected or emergency button pressed) within this period, the alarm is cancelled, otherwise EasyAlarm
®
establishes a hands-free connection
6.) Sensor-2 activation according to 5.2.
7.) Noise monitoring according to 5.4: To avoid false alarm while acoustical monitoring, close windows and try to
eliminate sources of noise.
8.) EasyAlarm
®
monitors mains voltage and triggers an alarm if power loss is longer than 10 to 20 minutes (=> time-out
according to section 10.4). During a pre warning period of 1 minute the following message is announced „Alarm due
to power failure“. After this period EasyAlarm® dials the programmed number and a hands-free connection is
established. If EasyAlar does not detect mains power during start up the monitoring remains inactive => „Power
failure“ is announced ! As soon as mains power is detected, EasyAlarm® starts to supervise mains power
Alarm release renewed
After an alarm EasyAlarm® remains inactive during a waiting period of two minutes. Only if at expiration of this
waiting period an alarm event occurs again, a new alarm is released. After an alarms through to sensor-1/2/3 a renewed
alerting comes off only if to the alarm contact returned to the state of rest.
Tone-dialling commands
DTMF => Every valid command will be signalled
0 Terminate phone connection and acknowledge alarm
1 Switching to hands-free mode and restart connection time-out
2 Repeat announcements (Individual message / Cause of alarm)
3 Restart connection time-out (2 minutes)
4 Deactivate output (i.e. switching off alarm siren)
5 Announcement of current supervision mode as well as condition of the output
6 Activate output (i.e. switching on the alarm siren)
7 Change to inactive supervision mode (I, II, III) => monitoring for noise, sensor-1, sensor-2, mains failure and
presence verification inactive. Emergency call and sensor-3 alarm are still possible.
8 Terminate phone connection without acknowledgment
9 Change to active supervision mode (I, II, III) => All monitoring functions re-activated
Noise
Nois
4 seconds
4 seconds
4 seconds 4 seconds
Telephone connection
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for EasyAlarm CONTROL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of EasyAlarm CONTROL in the language / languages: English as an attachment in your email.

The manual is 0,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of EasyAlarm CONTROL

EasyAlarm CONTROL User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info