319303
1
Zoom out
Zoom in
Previous page
1/2
Next page
To empty clear bin, pull back release catch under carrying handle
and raise top of machine.
Lift clear bin out of machine. Remove cyclone top (lid).
Wrap a plastic bag
tightly around the rim
of the clear bin.
Self adjusting
Floor tool
Fit floor tool by pushing
firmly into end of wand.
Tool storage
Press yellow release catch to open the tool
storage cover and insert required tool into
end of wand or wand handle. Please
note that tools may feel warm when
machine has been running; this is
perfectly normal.
Clear bin full mark
Note: Do not fill above this line.
Sits securely
on the stairs
However, always
work above the
machine on stairs for
your own safety.
Do not use strong
detergents and ensure
clear bin is fully dry before
replacing in machine.
Note: The yellow bin inner
should not be removed from
the bin when it is cleaned.
2. Clear bin removal
On/off switch
Press left switch.
Cord rewind
Press right switch for cord rewind.
1. Hose & wand
assembly
Assemble hose and wand by fitting
together at joints , , and . Push
yellow cuffs in until both buttons ‘click
into place.
Press buttons and pull hose to release.
Telescopic wand
Press yellow button and
slide wand down to
adjust length.
2
max
The plug is situated
underneath the tool
cover on the right
hand side.
click
OPTIONAL
1
click
2
3Blockage procedure
Please note: Any ‘Blockage only’ repairs will incur a
charge of $60.00*
. Please check your machine carefully.
Check filters, replacing S-level if older than 3 months
and HEPA if older than 12 months, or if filters are heavily
coated with dust.
*Price correct at time
of printing.
1
4. Remove floor tool from
wand πand check for
blockage.
2. Check wand handle swivel
by pressing yellow buttons and
pulling hose from wand. Clear
any debris.
5. Check air intake hole and check ramp.
2
4
Invert clear bin and wait at least
10 seconds before releasing.
Wipe shroud holes
free of all dust/debris.
max
1
Replace clear bin and cyclone
top and close machine.
Ensure release catch
‘clicks’ into position before
using the vacuum cleaner or
lifting the machine by the
carrying handle.
2 3
4 5
6 7
8
Changing filters
Your DCO2 is fitted with one H-level electrostatic cartridge
filter and one HEPA filter.
Insert top H-level electrostatic filter ensuring that it fits
snugly against the black rubber seal on the machine.
Slide purple HEPA filter into the grooves and push it
down fully.
Automatic suction control trigger
Hold the yellow trigger down to reduce suction for
upholstery and curtains.
To maintain reduced suction, press the trigger down
hard until it clicks. To unlock and resume full suction,
press down the opposite end of the trigger.
1 3
WARNING! For your own safety please
remember to unplug the machine when not in
use and before carrying out maintenance.
3. Check wand joint
by pulling wand
and wand handle
apart. Clear any blockage
with rod or wire.
1. Check entry swivel by
pressing yellow buttons &
pulling out hose.
Clear any debris.
1
2
33
4
IMPORTANT Use only genuine Dyson filters.
1
1
221 H-level
1 HEPA
&
Wand
handle Wand
H-Level
H
Absolute
HEPA
Bactiguard
DC02 ABS Operating Manual 30-08-1999 14:25 Page 1
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dyson dc 02 absolute at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dyson dc 02 absolute in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dyson dc 02 absolute

Dyson dc 02 absolute User Manual - English, German, Dutch - 9 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info