5 Pneumatic Connection
For the operation of the pneumatic components, the sewing unit must
be supplied with anhydrous compressed air.
ATTENTION !
For faultless functioning of the pneumatic control operations, the
compressed air network must be designed as follows:
Make sure that a minimum operating pressure of 6baris not
exceeded even when air consumption is at its highest.
In the event of excessive compressed a ir drop:
Increase the compressor performance.
Increase the diameter of the compressed air supply line.
Connect the compressed air maintenance unit
Connect the connecting hose 3 to the compressed air network.
Adjust the operating pressure
The operating pressure is 6 bar.
It can be read out on the manometer 1.
Lift up and tur n the turning handle 2 for adjusting the operating
pressure.
- Tur ning in clockwise direction = Increase pressure
- Tur ning in anti-clockwise direction = Reduce pressure
ATTENTION!
The compressed air network may not be used to supply oiled
compressed air.
Behind the filter, purified compressed air is extracted as blow air for
the cleaning of machine parts and for blowing out the sewing parts.
Oil particles that are entrained with the blow air lead to functional
faults and contamination of t he sewing parts.
8
32 1
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Durkopp Adler 1281-5-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Durkopp Adler 1281-5-1 in the language / languages: English as an attachment in your email.

The manual is 0,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Durkopp Adler 1281-5-1

Durkopp Adler 1281-5-1 User Manual - English - 62 pages

Durkopp Adler 1281-5-1 User Manual - German - 13 pages

Durkopp Adler 1281-5-1 User Manual - German - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info