Specifications
General Specifications
Voltage Rating . . . . . . . . . . . . . . . . . . . . . . . . .120 V, 60 Hz
Amperage Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.6 A
No Load Speed . . . . . . . . . . . . . . .N
o
500-1,700/min (SPM)
Throat
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18"
Blade . . . . . . . . . . . . . . . . . . . . . . . . . .5” plain and pin-end
Blade Stroke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4"
Cutting Capacity . . . . . . . . . . . . . . . . . . .1fl" at 0°, 1" at 45°
Motor Specifications
In the event of a malfunction or breakdown, grounding pro-
vides a path of least resistance for electric current to reduce
the risk of electric shock.
This Scroll Station is designed to use a variable speed RPM
motor. It is wired for operation on 110-120 volts, 60 Hz. alter-
nating current. Before connecting the motor cord to wall out-
let, make certain the power switch is in the OFF position and
be sure the electric current is of the same characteristics as
stamped on the Scroll Station nameplate.
Connection To A Power Source
This machine must be grounded while in use to protect the
operator from electric shock.
Plug power cord into a 110-120V properly grounded type out-
let protected by a 15-amp dual element time delay fuse or cir-
cuit breaker.
Not all outlets are properly grounded. If you are not sure that
your outlet, as pictured on this page, is properly grounded;
have it checked by a qualified electrician.
To avoid electric shock, do not touch the
metal prongs on the plug when installing or
removing the plug to or from the outlet.
Failure to properly ground this power tool can
cause electrocution or serious shock, particu-
larly when used near metal plumbing or other metal objects.
If shocked, your reaction could cause your hands to hit the
tool.
If power cord is worn, cut or damaged in any
way, have it replaced immediately to avoid
shock or fire hazard.
DANGER
!
DANGER
!
DANGER
!
Your unit is for use on 120 volts; it has a plug that looks like
the one in Figure 1.
This power tool is equipped with a 3-conductor cord and this
plug requires a mating 3-conductor grounded type outlet as
shown. It must be grounded in accordance with all local codes
and ordinances.
If the outlet you are planning to use for this power tool is of the
two-prong type, DO NOT REMOVE OR ALTER THE GROUND-
ING PRONG IN ANY MANNER. Have a qualified electrician
replace the TWO-prong outlet with a properly grounded
THREE-prong outlet.
Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. If repair or replacement of the
electric cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal.
Check with a qualified electrician or service personnel if the
grounding instructions are not completely understood, or if in
doubt as to whether the tool is properly grounded.
Always use proper extension cord. The use of any extension
cord will cause some loss of power. To keep this to a minimum
and to prevent overheating and motor burn-out, use the table
below to determine the minimum wire size (A.W.G.) extension
cord. Use only 3-wire extension cords which have 3-prong
grounding type plugs and 3-pole receptacles which accept the
tool’s plug. Make sure your extension cord is in good condition.
Extension Cord Length
Wire Size A.W.G.
0-25 feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
26-50 feet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
51-100 feet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
SAVE THESE INSTRUCTIONS
Figure 1. Grounded Wall Outlet
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dremel 1800 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dremel 1800 in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 1,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info