653186
1
Zoom out
Zoom in
Previous page
1/2
Next page
Combi-Stat RTS8
Room Thermostat
Installation
instructions
RELEVANT EC DIRECTIVES:
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic Compatibility
2011/65/EU RoHS Directive
APPLIED STANDARDS:
EN60730-1, EN60730-2-9
Energy Class I = 1% (According to EU 811/2013,
812/2013, 813/2013, 814/2013)
Telephone: +44 (0) 845 130 5522
Facsimile: +44 (0) 845 130 0622
Technical Helpline: +44 (0) 845 130 7722
Website: www.draytoncontrols.co.uk
Email: customer.care@draytoncontrols.co.uk
6490018-1 Iss D
0503
Drayton Controls reserve the right
to make changes without notice
and cannot accept liability for errors.
THERMOSTAT INTERCHANGE GUIDE
deifsitaSdnameDnommoCeviLlartueNhtraEledoMekaM
3LN1SRsaG hsitirB
British Gas RS2 (for 2 wire connectionwith loads of 0.1 to 0.6 A) L 2
British Gas RS2 (for 2 wire connection with loads 0.6 to 6A) L 3
British Gas RS2 (for 3 wire connection with loads under 2A) N L 3
231LN4SR saG hsitirB
Drayton RTS7 and RTS8 (for 2 wire connection with loads of 0.1 to 0.6 A) L 2
Drayton RTS7 and RTS8 (for 2 wire connection with loads 0.6 to 6A) L 3
Drayton RTS7 and RTS8 (for 3 wire connection with loads under 2A) N L 3
3LN 1 STRnotyarD
3LN 2 STRnotyarD
231 LN4 STRnotyarD
214E241 STelytsefiL LCA
2315053 AT elytsefiL LCA
Drayton (old version) 3214 TR
Drayton (old version) 4ETR 123
3214032TMRlladnaR ssofnaD
43LN032TERlladnaR ssofnaD
Danfoss Randall RT1 132
2143DR lladnaR ssofnaD
214A3DR lladnaR ssofnaD
213NECTR lladnaR ssofnaD
213NEMTR lladnaR ssofnaD
213NERSR lladnaR ssofnaD
213N405R lladnaR ssofnaD
Honeywell T4360B 1 3
4312B0606T llewyenoH
4312B1606T llewyenoH
4312B3606T llewyenoH
4312B0636T llewyenoH
214E1TRH nnamtsroH
Horstmann Centuarstat 123
321E1 DAR ryG & sidnaL
Landis & Gyr RAD 1N 123
Landis & Gyr RAD 1EM 123
HLN1 TRP notrettoP
HLTN 2 TRP notrettoP
HLTNTS 001 TRP notrettoP
CHLTNTD 001 TRP notrettoP
134E2222 XLTcivnuS
13/LNE9522 XLT civnuS
213NE6532 XLT civnuS
134E4562 XLTcivnuS
2134E2582 XLTcivnuS
231E053 AT capoS
2314E153 AT capoS
23152 TRS retsamhctiwS
214ESS rewoT
NOTE: British Gas RS2 & Drayton RTS7 details are for guide use only. ALWAYS follow above instructions.
TECHNICAL DATA
Electrical supply 24V-230V AC/DC
Double insulated no earth
required
Temperature range 10°C to 30°C
Switch type SPST 6(2)A
See Figs 5 to 7 for supply
voltage and maximum loads
which are dependant on
wiring configuration used
Temperature sensor Bi metallic
Continued from overleaf
Combi-Stat boiler compatibilty information
Make Model
Alpha 240 2 wire
Ocean 80 3 wire
Ariston Genus 27 2 wire
Euro Combi 27 2 wire
Biasi Prisma 2 wire
Riva 3 wire
Chaffoteaux Britony Combi 80 3 wire
Celtic FF 3 wire
Ferrolli Domina 80 2 wire
Modena 80 2 wire
Halstead Finest 2 wire
Finest Gold 2 wire
Radiant RSF 24 2 wire
Ravenheat RSF 820/20 2 wire
CSI 85 Condensing 2 wire
Saunier Duval 623 Combi 2 wire
Myson Midas BF 2 wire
Elm Le Blanc 2 wire
CombiStat
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Drayton Combi-Stat RTS8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Drayton Combi-Stat RTS8 in the language / languages: English as an attachment in your email.

The manual is 0,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info