499507
42
Zoom out
Zoom in
Previous page
1/44
Next page
- 42 -
0DT829 15/10/2012
Part Part number
Cycles / hour
Abusive
Environment
(1)
<10 <30 >30
  
Limit switch group 6K10GF
36 24 12 12
Limit switch 5M
48 36 24 24
Brake disc 21572
36 24 12 12
Brake disc guide 21571
36 24 12 12
Safety edge coiled cable 27795B
36 24 12 12
Belt counterweight and curtain 6KTFCS
36 24 12 12
(1) Dirty or dusty environment, operating temperature near to 0°C or over 35°C, wind pressure within 20% of maximum limit.
Date Conter Signature
8. MAINTENANCE TO BE CARRIED OUT EVERY 6 MONTHS
Regular inspections should be made according to national regulations and product documentation by a Ditec Entrematic
trained and qualied technician. The number of service occasions should be in accordance with national requirements and
product documentation.
Installation / Fitting
• Tighten the tting screws of the uprights with the crosspiece
• Check the anchoring of the door to the door frame
Motor
• Check the xing of the motor to the relevant support
• Check the tensioning of the transmission chain
• Check the limit switches functioning and the good alignment with the cams.
• Check the brake disc wearing. If necessary replace the disc
• Check the properly manual release lever brake functioning (when applicable)
Main Shaft / Belt
• Check the good bearing supports xing
• Lubricate the support of the bearings by suitable grease inlet
• Check the wear and tear of the counterweight belts and the curtain. Replace the belts if necessary
Safety Devices
• Check the good safety bar functioning
• Check the good conditions of the safety bar rubber prole
• Check the adjusting and the eventual wearing of the steel cable of the electromechanical safety edge
• Check the wearing of the mobile cable
• Check the correct operation of the safety photocells
8.1 Maintenance Plan
The table below shows the recommended interval - in months - when to replace parts during preventive maintenance.
Date Conter Signature
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DITEC Traffic CM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DITEC Traffic CM in the language / languages: English, Dutch as an attachment in your email.

The manual is 2,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info