798062
4
Zoom out
Zoom in
Previous page
1/24
Next page
2.1 - Storage
STORAGE AND INSTALLATION
PRECAUTIONS:
•The appliance must not be stored in an enclosed
space of less than 4m
2 without ventilation.
• If the appliance is to be stored in a space with
less than 4m2 of surface area (e.g. in a cupboard)
there must be ventilation points at the top and
bottom of this space.
Authorised transport positions :
All other transport positions are prohibited.
2- RECOMMENDATIONS
Verify that the ventilation openings are not
obstructed.
• A new pressure-relief valve (not included) must
be installed and set to 6 bars on the domestic
cold water supply of the appliance. The use of
a membrane valve is recommended.
This valve must conform to all national standards
in eect.
The pressure-relief drainage outlet should
be installed in a frost-free place and in a
downward sloping position.
- Maintenance - Troubleshooting -
• Drainage : Turn o the power supply and the
cold water, open the hot water valves and then
set the safety group to the drainage position.
The pressure-relief valve should be activated
regularly so as to eliminate limescale and check
for blockages.
•.If the electrical supply cable is damaged, it
must be replaced by the manufacturer, their
customer service technicians, or by a qualied
professional to avoid risk of injury.
• See the § «Dimensions» (page 5) and the §
«Installation» (page 6) of this manual to nd the
necessary dimensions for proper installation of
this appliance.
• See the § «Hydraulic connections» (page 7) of
this manual to nd the minimum and maximum
water pressures and temperatures.
WARNING
Do not use any methods to accelerate the
defrosting or cleaning process other than
those recommended by the manufacturer.
The appliance must be stored in a room which
does not contain a perpetual ame or other
source of ignition (for example: open ame,
gas powered appliances or electric radiators
in use).
Do not pierce or burn.
Warning: refrigerant uids may be odourless.
The appliance must be installed, used, and
stored in a room larger than 4m².
The appliance can only function when filled
with water. Never turn on the appliance if the
tank has not been properly filled with water
and completely purged of air.
2.2 - Transport
Admissible transport and storage temperatures of the heat pump
water heater are between -20oC and +60oC.
Transporting the appliance in a
horizontal position may lead to
irreparable damage to the components of the
Heat Pump.
All other transport positions are
PROHIBITED.
It is preferable to transport the heat pump water heater in its original
packaging to protect the appliance.
Non-authorised transport positions :
- INSTALLER HEAT PUMP WATER HEATER 200 -270L AIR D/2 - MANUAL-
4
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex Edel 270 AIR D-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex Edel 270 AIR D-2 in the language / languages: English as an attachment in your email.

The manual is 2.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex Edel 270 AIR D-2

Dimplex Edel 270 AIR D-2 User Manual - Dutch - 48 pages

Dimplex Edel 270 AIR D-2 Installation Guide - Dutch - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info