Display Error Probable causes Solutions
Temporary operation measures
while waiting for problem to be
solved
ERR.01
•Incorrect temperature sensor
reading
•The air and defrosting sensors are
inverted on the electronics board
•The defrosting and water sensors
are inverted on the electronics
board
•The defrosting sensor is
connected to the air input, the
air sensor is connected to the
water input, the water sensor is
connected to the defrosting input
•Reposition the temperature
sensors correctly on the main
electronics board
•Heat pump non-functional
•Incorrect reading from the
defrosting sensor
•The defrosting sensor is not
properly connected to the tube
and is measuring air
•Reposition the defrosting sensor
properly in the tube
•The heat pump has run out of
refrigerant uid
•There is a leak in the refrigerant
circuit
•Find and repair the leak before
lling the refrigerant circuit
•The expansion valve is not
working
•The expansion valve bulb is
damaged or broken due to
work being carried out on the
appliance, or it being in contact
with a part that vibrates
•Replace the expansion valve
•The compressor is not working
and safety temperature is
activated
•Defect in compressor •Replace the compressor
ERR.02 •Incorrect temperature sensor
readings
•The air and water sensors are
inverted on the electronics board
•The defrosting sensor is
connected to the air input, the
air sensor is connected to the
water input, the water sensor is
connected to the defrosting input
•Reposition the temperature
sensors properly on the main
electronics board
•Appliance non-functional
ERR.03 •Incorrect temperature sensor
readings
•The defrosting sensor is
connected to the air input, the
air sensor is connected to the
water input, the water sensor is
connected to the defrosting input
•Reposition the temperature
sensors properly on the main
electronics board
•Appliance non-functional
ERR.04 •Incorrect defrosting and water
sensor readings
•The defrosting and water sensors
are inverted on the electronics
board
•Reposition the temperature
sensors properly on the main
electronics board
•Heat pump non-functional
ALARME
EPR0
•The display screen electronics
board has a memory problem
•The display screen of the
electronics board is damaged
•Replace the display screen of the
electronics board •Appliance non-functional
ERR.08 •Incorrect defrosting sensor
readings •The defrosting sensor is defective •Replace thge sensor •Appliance in alternative mode
- INSTALLER HEAT PUMP WATER HEATER 200 -270L AIR D/2 - MANUAL-
20
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Dimplex Edel 200 AIR D-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Dimplex Edel 200 AIR D-2 in the language / languages: English as an attachment in your email.

The manual is 2.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Dimplex Edel 200 AIR D-2

Dimplex Edel 200 AIR D-2 User Manual - Dutch - 48 pages

Dimplex Edel 200 AIR D-2 Installation Guide - Dutch - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info