Attach the ange accessory B1 provided to the hole.
Fit the adapter B3 in the air exhaust hose housing A7 on
the back of the appliance (see g. 1).
Screw the wall mounting accessory B4 on the air exhaust
hose B2. If necessary, remove the other adapter B3 from
the air exhaust hose B2 by unscrewing it (g. 10).
Screw the hose on the machine.
Fit the end of the hose B2 to the ange B1 as shown in g.
9.
Whenever the hose B2 is not attached, the hole can be
closed using the cap for the ange B1.
NOTE: for semi-permanent installations, we recommend leav-
ing a door slightly open (even just 1 cm) to ensure the proper
air exchange.
CONTROL PANEL page. 4  C
CONTROL PANEL DESCRIPTIONS
C1 ON/STAND-BY (on/o) key
C2 Function selection key MODE (air conditioner,
dehumidier, fan)
C3 Temperature increase key
C4 Temperature decrease key
C5 Fan speed selection key (MIN/MED/MAX/AUTO)
C6 REAL FEEL status indicator
C7 Air conditioner symbol
C8 Dehumidier symbol
C9 Fan symbol
C10 Timer symbol
C11 Alarm symbol
C12 Swing symbol
C13 SILENT symbol
C14 Set temperature values, programmed on/o time
C15 Fan speed indicator
C16 Timer indicator
C17 Selected temperature scale indicato
CONTROL PANEL OPERATION
TURNING THE APPLIANCE ON AND OFF (g. 11)
Insert the plug in the socket. Two dashes appear on the display
indicating that the appliance is in stand-by
Touch the (C1) key to turn on the appliance.
Il ap A1 will open after few seconds.
When the appliance comes on, the last function set before it was
shut o is activated.
NOTE: If start-up is not continued, after a few minutes the
display light dims in order to reduce energy consumption.
To turn the appliance o, touch the , key and then pull the
plug.
NOTE: Never turn o the air conditioner by simply pulling the
plug. Touch the key in order to put your air conditioner in
stand-by and wait a few minutes before pulling the plug. In this
manner, the appliance can perform the operating status checks.
AIR CONDITIONER MODE (g. 12)
This is ideal for hot and humid weather when the room needs to
be both cooled and dehumidied.
To correctly set this mode:
Touch the MODE key until the air conditioning symbol ap-
pears. The display will show the desired temperature.
To change the temperature to be reached, touch the + (C3)
key or the - (C4) key.
Select the desired fan speed by touching the key.
The speeds available are:
Minimum speed: when maximum silent operation is
desired.
Medium speed: when the noise level needs to be
low but with a good comfort level.
Maximum speed: to reach the desired tempera-
ture as soon as possible.
The appliance automatically chooses the best
fan speed based on the temperature selected and the environ-
mental conditions.
The most suitable temperatures during the summer range from 24
to 27°C. However, setting the temperature signicantly lower than
the outdoor temperature is not recommended.
DEHUMIDIFIER MODE (g. 13)
This is ideal for reducing humidity in the room (spring and au-
tumn, damp rooms, rainy periods, etc.)For this type of use, the
appliance must be set up as for air conditioner mode. That is, the
air exhaust hose (B2) must be tted to the appliance to allow the
humidity to be discharged outside.
To correctly set this mode:
Touch the MODE key until the dehumidier symbol appears.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DeLonghi PACEX120 Silent Pinguino at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DeLonghi PACEX120 Silent Pinguino in the language / languages: English as an attachment in your email.

The manual is 1.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DeLonghi PACEX120 Silent Pinguino

DeLonghi PACEX120 Silent Pinguino User Manual - English - 36 pages

DeLonghi PACEX120 Silent Pinguino User Manual - German - 15 pages

DeLonghi PACEX120 Silent Pinguino User Manual - Dutch - 9 pages

DeLonghi PACEX120 Silent Pinguino User Manual - Dutch - 9 pages

DeLonghi PACEX120 Silent Pinguino User Manual - French - 36 pages

DeLonghi PACEX120 Silent Pinguino User Manual - French - 9 pages

DeLonghi PACEX120 Silent Pinguino User Manual - Italian - 9 pages

DeLonghi PACEX120 Silent Pinguino User Manual - Spanish - 36 pages

DeLonghi PACEX120 Silent Pinguino Additional guide - All languages - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info