TIPS FOR CORRECT USE
To ensure optimal results from your air conditioner, follow these
recommendations:
Close the windows and doors in the room to be air condi-
tioned. When installing the air conditioner semi-perma-
nently, you should leave a door slightly open (as little as 1
cm) to guarantee proper ventilation.
Never use the appliance in very damp rooms (laundries for
example).
Protect the room from direct exposure to the sun by par-
tially closing curtains and/or blinds to make the appliance
much more economical to run.
Never use the appliance outdoors.
Make sure there are no heat sources in the room.
make sure the air conditioner is standing on a level surface.
do not cover the appliance
Never rest objects of any kind on the air conditioner.
Never obstruct the air intake or outlet grilles.
CLEANING
Before cleaning or maintenance, turn the appliance o by
touching the
C1C2
C4
C14
C11
C9
C7
C5
C6
C3
C15
C10
C16
C13
C12
C8
button, then unplug from the outlet.
CLEANING THE CABINET
You should clean the appliance with a slightly damp cloth then
dry with a dry cloth. For safety reasons, never wash the air con-
ditioner with water.
Attention! Never use petrol, alcohol or solvents to clean the ap-
pliance. Never spray insecticide liquids or similar.
CLEANING THE AIR FILTER OR SILVER ION AIR FILTER
(on some models only)
The silver ion air lter helps capture dust and pollen and helps
reduce the growth of bacteria and mold on the lter.
If the lter is dirty, air circulation is compromised and the e-
ciency of the appliance decreases. It is therefore good practice
to clean the lter at regular intervals. The frequency depends
on the duration and conditions of operation. If the unit is used
constantly or systematically, you are recommended to clean the
lter once a week.
The lter is housed in the intake grille. To clean the lter, extract
as shown in g. 11.
Use a vacuum cleaner to remove the dust collected on the lter.
If it is very dirty, immerse in warm water and rinse a number of
times. The water should never be hotter than 40°C.
After washing the lter, allow it to dry completely before
repositioning it.
START OF SEASON CHECKS
Make sure the power cable and plug are undamaged and the
earth system is ecient.
Follow the installation instructions precisely.
END OF SEASON OPERATIONS
To drain all water from the circuit, remove the external cap by
unscrewing it in the anticlockwise direction (g. 12) and allow
the water to drain out into a basin.
When the appliance is empty, replace the cap.
Clean the lter and dry thoroughly before putting back.
TECHNICAL SPECIFICATIONS
Power supply voltage see rating label
Max. absorbed power
during air conditioning
Refrigerant
Cooling capacity
LIMIT CONDITIONS
Room temperature for air conditioning 18° ÷ 35°C
Room temperature for heating 10° ÷ 27°C
Transport, lling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
centre appointed by the manufacturer only.
The appliance should be disposed of by a specialist centre
appointed by the manufacturer only.
Attention! TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit
has been on its side, oil needs to return to the compressor to en-
sure proper function. Without allowing the unit this time (6-24
hours) the unit may function for only a short time, and then the
compressor will break down from lack of oil.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for DeLonghi PAC EL92 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of DeLonghi PAC EL92 in the language / languages: English as an attachment in your email.

The manual is 2.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of DeLonghi PAC EL92

DeLonghi PAC EL92 User Manual - German - 8 pages

DeLonghi PAC EL92 User Manual - Dutch - 8 pages

DeLonghi PAC EL92 User Manual - French - 8 pages

DeLonghi PAC EL92 User Manual - Italian - 8 pages

DeLonghi PAC EL92 User Manual - Spanish - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info