348
16
Zoom out
Zoom in
Previous page
1/20
Next page
16
Function 1: Cause of Alarm trigger
Press button A to obtain information about the cause of the alarm last triggered. Press button B for
information about the alarm triggered previously. Hold button B to return to the last alarm.
Hold buttons A and B simultaneously to delete the trigger cause memory.
The Central Unit can store up to 10 alarm events.
Alarm triggered by: Number of flashes
Auxiliary Sensor 1 2
Open door 3
Open bonnet 4
Open luggage compartment lid 5
Ignition 6
Attempt to remove secured object (stereo, ski box, etc.) 7
Microwave Sensor 8
Glassbreake Sensor 9
Auxiliary Sensor 2 10
Function 2: Number of Remote Control Units
Press button B to learn how many Remote Control Units are connected to the alarm. The number of
units is indicated by the number of flashes.
Function 3: Alarm sounds
Press button B to activate the set alarm sound for 5 seconds. Press button B again to select the next
alarm sound and hold button B to return to the previous sound. A total of 6 different sounds are
available.
Function 4: Passive arming
Passive arming means that the alarm is switched on 12 seconds after the ignition is switched off and the
doors are closed.
Press button B to indicate:
1 flash if active arming is selected
2 flashes if active arming is selected regardless of the opened door.
3 flashes if passive arming is selected.
Press button B again to select the next function. The number of confirmation sounds indicates the status
currently set.
Function 5: The sensitivity of the Microwave Sensor
For Control purposes the sensitivity level of the detector is indicated by a number (1- 8) of short signals
in the LED.The lowest level is 1, the highest is 8. Factory setting is 3.
Press button B to indicate the valid sensitivity level. Press button B to increases the sensitivity level
while holding button B reduces the level. The number of flashes in the LED indicates the level. Selected
sensitivity level is confirmed by releasing the detector. Last choosen step will be selected sensitivity
level.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Defa 800 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Defa 800 series in the language / languages: Dutch as an attachment in your email.

The manual is 1,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info