5. Checking and maintenance
The last ten failures are memorised in the paragraph #DEF.
HISTORY
6.2.3 Control panel K3
No error messages displayed. See DIEMATIC-m3 control panel
display.
6.3 Incidents and solutions
The burner is not working:
- Check the boiler thermostat settings.
- Shutdown by the safety thermostat due to accidental overheating
Check that the safety thermostat has not triggered. To restart the
boiler, reset the safety thermostat. Remove the safety thermostat
hood and press the reset button with a screwdriver. Carry out the
start-up operations again. Call your fitter.
- Check the circuit breaker
- The safety control box is malfunctioning (Error warning light
illuminated)
Press the resetting button of the burner. Call your fitter.
The burner is operating but the radiators are cold:
- Bleed the radiators.
- Top up the primary circuit with water.
If it is often necessary to top up the installation with water, contact
your fitter.
- Check that the heating pump is operating correctly.
- Check the position of the 3 position switch.
Control panel B3: TEST-STB/
.
/
%
on
.
.
Control panel DIEMATIC-m3: AUTO/
!
/TEST STB on AUTO.
Control panel K3: AUTO/
!
/TEST STB on AUTO
- Check the boiler thermostat settings.
TA-S SHORT-CIR The Titan Active System® is short-circuited.
Domestic hot water production is shut down and can be restarted using key
. The tank is no longer protected.
Advise the installer.
TA-S DISCONNEC The Titan Active System® is on an open circuit.
Domestic hot water production is shut down and can be restarted using key
. The tank is no longer protected.
Advise the installer.
TA-S FAILURE Internal problem.
Switch off the current.
Advise the installer.
Message Probable causes Action
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich DTG 330 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich DTG 330 in the language / languages: English as an attachment in your email.

The manual is 1,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info