FFOORR TTHHEE FFIITTTTEERR
As a specialist, you alone are competent to install and connect up De Dietrich appliances.
Our guarantee therefore applies only and exclusively to appliances which have been installed and connected up by
you in accordance with the provisions of current regulations.
Failure to meet this requirement would incur the fitter's liability and release the De Dietrich company from
any liability.
1. Connections
2. Technical characteristics
11
1) CONNECTIONS
Connecting to the mains.
When the cable (H05 RR-F 3x1,5mm
2
, H05 RN-F 3x1,5mm
2
or H05 VV-F 3x1,5mm
2
) requires changing, uns-
crew the screws on the connectors completely before inserting conductors into the appropriate terminals.
The protective conductor must be connected to the terminal on the apparatus.
If you wish to make a permanent connection, put an all-pole circuit breaker with a minimum contact opening of
3mm in the circuit. Under all other conditions, position the oven so that the plug is within easy reaching distance
especially if the oven is built-in.
We cannot be held responsible for any accident resulting from an inexistent or incorrect earth line.
Operating voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V ~ 50 Hz
Total power consumption ....................................................................................... 2,03 kW
Energy consumption
-while heating to maintain 200°C for 1 hour ....................................................... 0,70 kWh
Inside dimensions of oven
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38,5 cm
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18,2 cm
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33,5 cm
Effective volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23,5 litres
This apparatus complies with 73/23/CEE and 89/336/CEE directives.
min.
network voltage connection diameter of fuse
cable
230V~ 50Hz 1 Ph + N 3x1,5 mm2 16 A*
400V 3N~ 50Hz 1 Ph + N 3x1,5 mm2 16 A
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for De Dietrich DOV 101 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of De Dietrich DOV 101 in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info