CONNECTIONS
USB Client Connection
Connect the Single Slot Dock to the host by means of a Micro-B USB
cord, such as Datalogic 94A051968 cable.
Once the host has been turned on, insert the Skorpio X3 into the cradle.
Figure 7 - USB Connection
Key:
A) Host computer
B) 94A051968 Micro-B to Std-A USB straight cable
C) 94A150031 Skorpio X3 Single Slot Dock
D) 94ACC1381 Power Adapter
Connection to USB peripherals
Connect the Single Slot Dock to the peripheral by means of a Micro-A
USB cord, or use a Micro-A to Std-A receptacle USB adapter such as
Datalogic 94A051969 (together with a standard USB cable if needed).
Figure 8 - USB Peripheral Connection
Key:
A) USB Peripheral (memory)
B) Standard A to Micro A USB Cable
C) 94A051969 Micro-A to Std-A receptacle USB adapter
D) 94A150031 Skorpio X3 Single Slot Dock
E) 94ACC1381 Power Adapter
RS232 Connection
Connect the Single Slot Dock to the host by means of a standard null
modem cable such as Datalogic 94A051020 CAB-427 for 9-pin
connections.
Once the host has been turned on, insert the Skorpio X3 into the cradle.
Figure 9 – RS232 Connection
Key:
A) Host computer
B) 94A051020 9-pin serial cable
C) 94A150031 Skorpio X3 Single Slot Dock
D) 94ACC1381 Power Adapter
Communication Module Extensions
To install a communication module, remove the label covering the
communication module connector on the bottom of the cradle, as
shown in the figure below:
Figure 10
The communication modules available are the following:
94ACC1371 Single Slot Dock Ethernet Module
94ACC1372 Single Slot Dock Modem Module.
TECHNICAL FEATURES
Electrical Features
Power supply * 5 VDC ± 5% @ 3A
Consumption Max 3 A with mobile computer inserted
Spare slot charge time
Skorpio X3 Std
Battery
1h 30
Skorpio X3
High Cap
Battery
6h 30 (with mobile computer inserted)
5h (when mobile computer is not inserted)
Communication Features
Interface RS232, USB 1.1 version
Baud Rate RS232 = 9600 - 115200
Physical Features
Dimensions 110 x 140 x 72 mm
4,3 x 5,5 x 2,8 in
Weight (without
connection cables)
185 g / 6,5 oz
Indicators Green power-on LED
Bicolored battery charge status LED
Environmental Features
Working temperature** -10° to +50°C / 14° to 122°F **
Storage temperature -20° to +70°C / -4° to 158°F
Humidity 95% without condensation
Electrostatic discharge
EN 61000-4-2
4 KV contact / 8 KV air
* Use only DL approved power adapters.
** Skorpio X3 (including spare battery) should be charged at an ambient
temperature between 0 - 35º C to achieve the maximum charging rate.
Never charge the main device or spare batteries in a closed space
(cabinet) where excessive heat can build up.
FCC COMPLIANCE
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
This device has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiated radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for
help.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user‘s authority to operate the equipment.
A
B
D
C
A
B
D
C
A
D
B
C
E
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic Skorpio X3 Single Slot Dock at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic Skorpio X3 Single Slot Dock in the language / languages: English as an attachment in your email.

The manual is 0,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info