535544
1
Zoom out
Zoom in
Previous page
1/2
Next page
1x
1x
1x
1x
Magellan
TM
83/8400 Calibration Process Quick Reference Sheet
1 2 3 4
5 6 7 8
Ensure that the Scanner-
Scale is powered-on (the
green top LED and orange
>0< button will be lit or
flashing).
Return the wire lift handle
to its down position and
replace the Top Platter. (If
the Top Platter does not
seat correctly, recheck to
see that the lift handle is
fully retracted.)
After ensuring the platter
is fully seated, press &
release the flashing >0<
button once. Wait for the
scanner to sound two
beeps. (The >0< button
will continue to flash.)
Place 20 lbs. of certified
weights on the platter and
press & release the >0<
button once. The scanner
will emit a trill sound upon
registering the weight.
Remove the weights from
the platter and press &
release the >0< button once
to complete the calibration
sequence. The scanner will
reset and the >0< button
will light steadily.
Remove the Top Platter
from the scanner-scale,
and locate the switch
door.
Open the calibration door
cover by pushing back
towards the optics
chassis. (It may be
necessary to push the
wire lift handle into the
upright position to access
the cover.)
Use your finger to reach
inside the calibration bay,
locate the small plunger
switch and press &
release it once. The
scanner will issue seven
rapid beeps and the >0<
button will begin to flash.
www. datalogic.com
© 2013 Datalogic, Inc. • All rights reserved.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U.
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Datalogic Magellan 8300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Datalogic Magellan 8300 in the language / languages: English as an attachment in your email.

The manual is 0,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Datalogic Magellan 8300

Datalogic Magellan 8300 User Manual - English - 20 pages

Datalogic Magellan 8300 User Manual - English - 540 pages

Datalogic Magellan 8300 User Manual - German - 24 pages

Datalogic Magellan 8300 User Manual - Spanish - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info