a. You can switch the thermostat OFF (Standby) by alternately pres-
sing . In OFF (Standby) mode the thermostat is set to a Frost Pro-
tection temperature setting and will switch On only if the measured
temperature falls below this temperature (5 °C by default).
b. The frost protect icon and current temperature will be display.
c. At this point if button is pressed for 10 seconds Continuously then
the thermostat will be reset.
User Settings
a. Press M button for 6 seconds to enter the parameter setting mode.
Press M for parameter selection and set the parameter range
via or . Complete all adjustments.
b. To exit press upper part of setting ring, or it will automatically exit
after 20 seconds when no button is pressed.
No.Parameter settingsSettings rangeDefault
02Heat control mode01: On/off load compensation
02: On/off standard01
04Temperature limit highBetween low (05) and 35 °C35 °C
05Temperature limit lowBetween 5 °C and high (04)5 °C
06Frost protect temperatureBetween 5 °C and 15 °C5 °C
07Holiday mode temperatureBetween low (05) and high (04)18 °C
10RF Pairing
(RET2001RF only)
00: RF pairing mode off
01: RF pairing mode on00
Need help? Post your question in this forum.
Report abuse
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Danfoss RET2001 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Danfoss RET2001 in the language / languages: English as an attachment in your email.
The manual is 0.78 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
The manual is sent by email. Check your email
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.