6. Charging can be stopped at any time by disconnecting the charger’s AC cord. Always disconnect the AC cord before 
disconnecting the battery leads. When you stop charging a battery installed in a vehicle you should always disconnect the battery 
lead from the chassis before disconnecting the other battery lead.
IMPORTANT INFORMATION FOR MULTI XT 14000 AND XT 14000
Please note that the battery pack in the 24V system in most cases consists of more than one battery. They are linked up to the 
24V system, but the individual batteries generally have a lower voltage. Therefore it is important for the charger to be connected 
correctly. 
BATTERY TYPES AND SETTINGS
The XS 25000 and XT 14000 are programmed according to “PROGRAM DESCRIPTION” with xed settings.MULTI XS 2500 and 
MULTI XT 14000 can easily be set for different types of batteries or conditions. The following recommendations should, however, 
only be seen as guidelines. Please consult the battery manufacturer for further instructions. 
Settings are made by pressing the “MODE-button “ and stepping forward one press at a time until the required mode is reached,
the button is then released. After about 2 seconds the charger activates the selected mode. The selected mode is saved in a 
memory in the charger and remains there even if the charger is disconnected from battery and mains.
NORMAL
NORMAL - Normal setting for wet batteries, maintenance free and for most Gel batteries. Some Gel batteries 
prefer a slightly lower charging voltage. Please consult the battery manufacturer when in doubt.
SUPPLY
SUPPLY - The charger operates at a constant voltage. This is the maintenance mode for applications where 
maximum capacity from the battery is important, like oor sweepers and golf carts. Note that the Spark
protection function is suppressed in this mode.
RECOND
RECOND - This mode is used to recover deep discharged ooded batteries where you could expect a
stratied acid (high acid weight in the bottom, low on top). Check with battery manufacturer when in doubt.
Use this mode with care, because the high voltage will cause some water loss. 16V is normally no problem for 
electronics in 12V system, or 32V in 24V system. Consult your supplier when in doubt. Life of light bulbs will 
be reduced at higher voltage. Try to disconnect light from the battery during this phase. Maximum effect and 
minimum risk for electronics is achieved by charging a disconnected battery.
CHARGING PHASES
MULTI XS 25000, XS 25000, MULTI XT 14000 and XT 14000 charges and analyses in eight fully automatic steps. 
MULTI XS 25000 and MULTI XT 14000 have three different operating modes, see Battery Types and Settings. 
The battery charger has an 8-step fully automatic charging cycle:
Desulphation
Desulphation with pulses recovers sulphated batteries. Indicates with lamp 1.
Soft start (Lamp 1)
Start mode for the charging cycle. The start phase continues until the battery’s terminal voltage has risen above the set limit, at 
which point the charger switches to bulk charging. If the terminal voltage has not passed the voltagelimit within the time limit, the 
charger switches to fault mode (lamp 0) and discontinues the charging. If so, the battery is faulty or its capacity is too large. 
Bulk (Lamp 2)
Main charge when 80% of charging takes place. The charger delivers maximum current until the terminal voltage has risen to the 
set level. Bulk has a maximum time, at which point the charger automatically switches to Absorption.
Absorption (Lamp 3)
Complete charge up to virtually 100%. The terminal voltage is maintained at the set level. During this phase the current tapers suc-
cessively. Once the current has tapered to the set limit, this phase switches to being timed. If the total time for Absorption exceeds 
the time limit the charger automatically switches to maintenance. 
Analysis (Lamp 3)
Testing self-discharge. If self-discharge is too high, charging is discontinued and fault mode is indicated. 
Maintenance charging - Float (Lamp 4)
Charging at constant voltage.
Maintenance charging - Pulse (Lamp 4)
State of charge varies between 95% and 100%. The battery receives a pulse when the voltage drops and keeps the battery in 
perfect condition when it is not in use. The charger can be connected for months at a time. The charger continuously measures 
the terminal voltage to determine whether a charging pulse should be initiated. If the battery is loaded and/or the battery’s terminal 
voltage drops the charger starts a charging pulse until the terminal voltage reaches the set level. The charging pulse is then 
discontinued and the cycle is repeated innitely. If the terminal voltage drops below a lower limit, the charger automatically goes
back to the beginning of the charging curve.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ctek XS 25000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ctek XS 25000 in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ctek XS 25000

Ctek XS 25000 User Manual - German - 9 pages

Ctek XS 25000 User Manual - Dutch - 8 pages

Ctek XS 25000 User Manual - French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info