652340
76
Zoom out
Zoom in
Previous page
1/80
Next page
76
10 Productspecications
10.1 Technical data
Heating voltage 230V/1~/50..60Hz
Unit model:
Basic Pro
5...8
Steam capacity in kg/h: 5...8
Max. power consumption in kW 3.8...6.0
Heating voltage 230V/3~/50..60Hz
Unit model:
Basic Pro Basic Pro Basic Pro Basic Pro Basic Pro Pro Pro
5...8 9...15 16...21 22...30 44/50/60 75/90 100/120
Steam capacity in kg/h: 5...8 9...15 16...21 22...30 44/50/60 75/90 100/120
Max. power consumption in kW 3.8...6.0 6.8...11.3 12.0...15.8 16.5...22.5 33.0/37.6/45.0 56.5/76.5 75.0/90.0
Heating voltage 400V/3~/50..60Hz
Unit model:
Basic Pro Basic Pro Basic Pro Basic Pro Basic Pro Pro Pro
5...8 9...15 16...25 26...45 52/60/70/80/90 105/120/135 152/160/180
Steam capacity in kg/h: 5...8 9...15 16...25 26...45 52/60/70/80/90 105/120/135 152/160/180
Max. power consumption in kW 3.8...6.0 6.8...11.3 12.0...18.8 19.5...33.8 39.0...67.5 78.8...101.3 114.0...135.0
Control voltage 1 x 230V / 50-60 Hz 2 x 230V / 50-60 Hz
Operating conditions
Admissible water pressure 1...10 bar
Water quality Untreated drinking water with a conductivity of 125...1250 uS/cm
Admissible water temperature 1...40 °C
Admissible ambient temperature 1...40 °C
Admissible ambient humidity max. 75% rh (non-condensing)
Admissible duct air pressure -0.8 kPa...1.5 kPa; overpressure kit (option) up to 10.0 kPa
Type of protection IP 20
Conformity CE, VDE, GOST
Dimensions/Weights
Housing (WxHxD) in mm 456x620x280 1 1 1 1
559x667x350 1 1 1 1 2 2 3 4
Net weight in kg 21 21 21 21 28 28 28 28 2x 28 2x 28 3x 28 4x 28
Operating weight in kg 26
26 32 32 65 65 65 65 2X 65 2X 65 3X 65 4x 65
Equipment/options
Steam cylinder type
(Type A.. standard equipment)
A3.../D3... 1 1
A4.../D4... 1 1
A6.../D6... 1 1 1 1 2 2 3 4
Steam hose connector
SC22 1 S
SC60 1 S
SC80 1 S 1 S 2 S S S
Steam hose connector
with condensate trap
SCCT22 1
SCCT60 1
SCCT80 1 1 2
Condensate trap CT22 1
CT60 1
CT80 1 1 2 3 4
Cable gland PG 1 S 1 S 1 S 1 S 1 S S S
Overpressure set OPS 1 1 1 1 1 1 1 1 2 2 3 4
Remote operating and fault indication RFI 1 S 1 S 1 S 1 S 1 S S S
Terminals heating voltage
M-THV 1 S 1 S
L-THV 1 S 1 S 2 S S S
Mounting prole MP 1 1 1 1
1 1 1 1 1 1 3 4
Internal control voltage with terminals
M-CVI 1 1 1 1
L-CVI 1 1 1 1 1 1 2 2
Transformer 400V/230V
M-Trafo 1 1 1 1
L-Trafo 1 1 1 1 1 1 2 2
Housing front cover, stainless steel
M-INOX 1 1 1 1
L-INOX 1 1 1 1 2 2 3 4
Accessories
Steam distribution pipe 41-... 1 1
61-... 1 1
81-... 1 1 1 1 2 2 3 4
Steam distribution system OptiSorp System 1 1 1 1 1 1 1 1 1
System 2 1 1
System 3 1
System 4 1
Fan unit
FAN3S CP ... M 1 1 1 1
FAN3S CP ... L 1 1 1 1 2 2 3 4
Steam hose / meter DS22 1 1
DS60 1 1
DS80 1 1 1 1 2 2 3 4
Condensate hose / meter KS10 1 1 1 1 1 1 1 1 2 2 3 4
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Condair CP3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Condair CP3 in the language / languages: English as an attachment in your email.

The manual is 3,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Condair CP3

Condair CP3 Usermanual and installation guide - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info