622509
1
Zoom out
Zoom in
Previous page
1/7
Next page
Operating Instruction CAWI Electronic Lock „ElCom“ 7205
1. General
Even though using this lock system is very easy, please read these operating instructions carefully and completely
before using the lock; this will help to avoid operating errors. These instructions refer to an electronic lock installed in a
high-security container such as a safe.
The green LED will blink to confirm each keypad entry. The time period between any two entries may not exceed 20
seconds as otherwise all previous entries will be cleared.
The keypad could be supplied with two differend keypad prints. (see Fig.1 and Fig.2)
Fig.1 Input of numerical acces code
e.g.
Fig.2 Input of alpha-numeric acces code
e.g. ROLF12
2. Opening the electronic lock
Enter the six-digit combination set at the factory by pressing buttons 1 2 3 4 5 6 or enter your own six-digit
combination.
Please note: Press the C button to correct your entry; in this case the entire combination will have to be entered again.
The green LED will light for about 6 seconds to indicate that the lock has been cleared for opening. At the same time,
the electronic lock will clear the mechanism for opening. The door to the safe can now be unlocked with the keypad lever
and opened using the fingertip grip. The electronic locking element is then locked again automatically after about 6
seconds; this is indicated by the red and green LEDs blinking once. The electronic lock is only secured when the keypad
lever is moved manually into its locked position.
3. Closing the electronic lock
Close the door to the safe and return the keypad lever to its locked position, moving it all the way to the mechanical stop.
The red cap must be completely concealed by the keypad lever. The green LED goes out at the same time to indicate
that the electronic lock has been mechanically secured in this position.
Please note: Try to operate the keypad lever to verify that the container is closed correctly and securely.
4. Response to erroneous entries
The red LED lights for about 3 seconds whenever an invalid combination is entered. The combination may now be
entered again. After the third consecutive incorrect entry, however, a 10-second time-out period starts; the keypad will
accept no entries during this period. This time-out period will be extended by 10 seconds following each subsequent
incorrect entry. The time-out periods cannot be interrupted with the ”C” button.
5. Correction with the C button
If you press the C button during the entry sequence, then the entire series of digits previously entered will be cancelled.
If a programming phase has been initiated, then the lock will exit the programming mode; you must re-start programming
from the very beginning by pressing the * button.
Exception: The time-out period following erroneous entries and the low-battery warning period cannot be interrupted by
pressing the C button.
1


Need help? Post your question in this forum.

Forumrules
1

Forum

cawi-elcom-7205

Reset search

  • bonjour
    la serrure ne fonctionne plus comment la changer Submitted on 2-8-2023 at 07:09

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for CAWI ElCom 7205 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of CAWI ElCom 7205 in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of CAWI ElCom 7205

CAWI ElCom 7205 User Manual - German - 2 pages

CAWI ElCom 7205 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info