624861
7
Zoom out
Zoom in
Previous page
1/7
Next page
Operation Guide 5176
E-60
If
ERR
keeps appearing during measurement, it could mean there is a problem with
the applicable sensor.
Whenever you have a sensor malfunction, take the watch to your original dealer or
nearest authorized CASIO distributor as soon as possible.
The barometric pressure differential pointer does not appear on the display
when I enter the Barometer/Thermometer Mode.
This could indicate sensor error. Try using
C
to re-enter the Barometer/
Thermometer Mode.
The barometric pressure differential pointer is not displayed when the displayed current
barometric value is outside of the allowable measurement range (260 to 1,100 hPa).
World Time Mode
The time for my World Time City is off in the World Time Mode.
This could be due to incorrect switching between standard time and daylight saving
time. See “To specify standard time or daylight saving time (DST) for a city” (page
E-43) for more information.
E-61
Specifi cations
Accuracy at normal temperature:
±30 seconds a month
Digital Timekeeping:
Hour, minutes, seconds, p.m. (P), month, day, day of the week
Time format: 12-hour and 24-hour
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Other: Home City code (can be assigned one of 48 city codes); Standard Time /
Daylight Saving Time (summer time)
Analog Timekeeping:
Hour, minutes (hand moves every 20 seconds)
Altimeter:
Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference
altitude
Display range: –10,000 to 10,000 m (or –32,800 to 32,800 ft.)
Negative values can be caused by readings produced based on a reference
altitude or due to atmospheric conditions.
Display unit: 5 m (or 20 ft.)
E-62
Measurement timing: 5-second interval for fi rst 3 minutes followed by 2-minute
interval for next 10 hours
Other: Reference altitude setting
Barometer:
Measurement and display range:
260 to 1,100 hPa (or 7.65 to 32.45 inHg)
Display unit: 1 hPa (or 0.05 inHg)
Measurement timing: 5-second interval for fi rst 3 minutes followed by 2-minute
interval for next 10 hours in the Barometer/Thermometer Mode
Other: Calibration; Barometric pressure differential pointer
Thermometer:
Measurement and display range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit: 0.1°C (or 0.2°F)
Measurement timing: 5-second interval for fi rst 3 minutes followed by 2-minute
interval for next 10 hours
Other: Calibration
E-63
Pressure Sensor Precision:
Conditions
(Altitude)
Altimeter Barometer
Fixed
temperature
0 to 6000 m
0 to 19680 ft.
± (altitude differential × 2%
+ 15 m) m
± (altitude differential × 2%
+ 50 ft.) ft.
± (pressure differential × 2%
+ 2 hPa) hPa
± (pressure differential × 2%
+ 0.059 inHg) inHg
6000 to 10000 m
19680 to 32800 ft.
± (altitude differential × 2%
+ 25 m) m
± (altitude differential × 2%
+ 90 ft.) ft.
Effect of
variable
temperature
0 to 6000 m
0 to 19680 ft.
± 50 m every 10°C
± 170 ft. every 50°F
± 5 hPa every 10°C
± 0.148 inHg every 50°F
6000 to 10000 m
19680 to 32800 ft.
± 70 m every 10°C
± 230 ft. every 50°F
Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
Precision is lessened by strong impact to either the watch or the sensor, and by
temperature extremes.
E-64
Temperature Sensor Precision:
±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)
World Time:
48 cities (31 time zones)
Other: Daylight Saving Time/Standard Time
Stopwatch:
Measuring unit: 1/100 second
Measuring capacity: 23:59' 59.99"
Measuring modes: Elapsed time, split time, two fi nishes
Countdown Timer:
Measuring unit: 1 second
Countdown start time setting range: 1 minute to 24 hours (1-hour increments and
1-minute increments)
Alarms:
5 Daily alarms; Hourly time signal
Illumination:
EL (electro-luminescent panel); Selectable illumination duration
(approximately 1 second or 3 seconds)
Other:
Low-temperature resistance (–10°C/14°F); Button operation tone on/off
E-65
Battery:
One lithium battery (Type: CR2016)
Approximate battery operating time: 3 years under the following conditions:
1 illumination operation (1.5 seconds) per day
10 seconds of alarm operation per day
10 hours of altimeter measurement, once per month
Frequent use of illumination runs down the battery.
City Code Table
City
Code
City
UTC Offset/
GMT Differential
PPG Pago Pago –11
HNL Honolulu –10
ANC Anchorage –9
YVR Vancouver
–8
LAX Los Angeles
YEA Edmonton
–7
DEN Denver
MEX Mexico City
–6
CHI Chicago
NYC New York –5
City
Code
City
UTC Offset/
GMT Differential
SCL Santiago
–4
YHZ Halifax
YYT St. Johns –3.5
RIO Rio De Janeiro –3
FEN
Fernando de
Noronha
–2
RAI Praia –1
UTC
0LIS Lisbon
LON London
L
City
Code
City
UTC Offset/
GMT Differential
MAD Madrid
+1
PAR Paris
ROM Rome
BER Berlin
STO Stockholm
ATH Athens
+2CAI Cairo
JRS Jerusalem
MOW Moscow
+3
JED Jeddah
THR Tehran +3.5
DXB Dubai +4
City
Code
City
UTC Offset/
GMT Differential
KBL Kabul +4.5
KHI Karachi +5
DEL Delhi +5.5
KTM Kathmandu +5.75
DAC Dhaka +6
RGN Yangon +6.5
BKK Bangkok +7
SIN Singapore
+8
HKG Hong Kong
BJS Beijing
TPE Taipei
L-1
City
Code
City
UTC Offset/
GMT Differential
SEL Seoul
+9
TYO Tokyo
ADL Adelaide +9.5
GUM Guam
+10
SYD Sydney
NOU Noumea +11
WLG Wellington +12
Based on data as of July 2010.
The rules governing global times (GMT
differential and UTC offset) and
summer time are determined by each
individual country.
L-2
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio 5176 - SGW-400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio 5176 - SGW-400 in the language / languages: English as an attachment in your email.

The manual is 0,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Casio 5176 - SGW-400

Casio 5176 - SGW-400 User Manual - German - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info