GENERAL OPERATION TROUBLESHOOTING GUIDE
Problem Probable causes Solutions
Entire spa is inoperative Power failure
RCD tripped
Heater high-limit thermostat tripped
Spa lock activated
Check power source
Reset RCD; call for service if it will not reset
Disconnect power for at least thirty seconds to reset heater high limit. If it will not reset,
check for clogged filters. If tripping continues, call for service.
Deactivate spa lock
Spa does not heat; jets and light
operate (Orange logo "Ready", and
Gray logo "Power" indicators are
blinking)
Integrated pressure switch open
Circulation pump thermal cut-off tripped
Check for clogged filters. Integrated pressure switch will reset when the flow of water
through the heater has been restored. Call for service if the heater trips frequently.
Check for clogged filters or air locks in plumbing. Disconnect power to the spa, allow
circulation pump to cool. Circulation pump thermal cut-off will reset when pump has
cooled and power is reapplied. Call for service if circulation pump thermal cut-off trips
frequently.
Jets weak or surging Spa water level too low
Filters clogged
Air valves are closed
Add water
Clean filters
Open air valves
Lights inoperative
Spa lock activated
Light wiring or assembly is faulty
Deactivate spa lock
Call for service, replace light assembly
Spa not heating properly Temperature set too low
Spa cover improperly positioned
Dirty Filter
Summer Timer On
Set control panel to a higher temperature.
Align spa cover
Clean filter
Turn summer timer mode to off position
Gray Logo "Power" indicator blinking Heater high-limit thermostat tripped Disconnect power for at least thirty seconds to reset heater high limit. If it will not reset,
check for clogged filters. If tripping continues, call for service.
Orange Logo "Ready" indicator blinking
Temperature sensor problem Disconnect power for at least thirty seconds. If blinking continues, call for service.
Orange Logo "Ready" indicator
flashing On 1 second and Off 3
seconds
Salt system issue Go to the Salt System menu on the control panel. Based on the Error Code displayed, follow
the instructions below:
Error Code 5
a. Using a FreshWater Salt test strip, verify that salt levels are at 1750 ppm. Add salt, per
salt system instructions as necessary.
b. Power down the spa, remove salt system housing cap and verify that a salt cartridge
is installed in the housing.
c. Contact your local Dealer if neither a. or b. resolves the problem
Error Code 4
a. Power down the spa, remove the salt system housing cap and remove the salt system
cartridge. Inspect the cartridge for damage. If damage is found the cartridge should be
replaced.
b. Using a FreshWater Salt test strip, verify the salt level. If the salt level is above 2500
ppm this may be the problem. If the salt level is above 2500 you will now need to
determine how much above 2500 ppm the salt level is by following the steps below:
a. Use a clean container and fill with 0.25 liter (8 ounces) of water from the spa
b. Remove 0.125 liter (4 ounces) of the spa water from the container
c. Then add 0.125 liter (4 ounces) of water from your household tap and mix to
combine
d. Using a new FreshWater Salt test strip, confirm the salt level of this new mixture
of spa and tap water
i. If the salt level is still at or above 2500 ppm, power down the spa, drain and
refill the spa with new water and follow the salt system start up instructions
ensuring that salt level is at 1750 ppm
ii. If the salt level is below 2500 ppm, the amount of salt in the spa is not
causing the error – contact your local Dealer for assistance
c. Contact your local Dealer if neither a. or b. resolves the problem
Pump motor will not function Motor overload condition
Control switch failure if jet symbol does
not come on
Let cool for one hour. Motor overload will reset automatically. If problem persists, contact your
CALDERA dealer
Disconnect spa and contact your CALDERA dealer
Surging pump or motor Low water level Add water to normal level (2.5 cm (1") above highest jet)
Pump motor runs, but low or no water/
jet pressure
Air control valve closed or blocked
Low water level
Dirty filter cartridge
Jet blocked
Clogged suction or skimmer basket
Open or clean air valve
Add water to normal level (2.5 cm (1") above highest jet)
Clean filter cartridge
Remove jet face eyeball and clean orifice
Clean suction cover or skimmer basket
Diverter valves are difficult to turn
Sand or grit inside valves
Clean and lubricate valve per diverter valve maintenance instructions.
After filling or refilling the spa: a jet
pump is operating, but water is not
flowing from any of its jets
Pump is not properly primed
Turn off power to the spa at the breaker and remove the equipment compartment door.
Loosen the union on the top of the pump(s) to allow the air to escape, and then hand-tighten
the union(s).
Turn power back on, activate the pump, and check to make sure the union is tight enough to
keep it from leaking. Replace the equipment doors.
Service Information
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Caldera Utopia - serie 2021 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Caldera Utopia - serie 2021 in the language / languages: English as an attachment in your email.

The manual is 10.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Caldera Utopia - serie 2021

Caldera Utopia - serie 2021 User Manual - German - 44 pages

Caldera Utopia - serie 2021 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info