684199
2
Zoom out
Zoom in
Previous page
1/6
Next page
11
CAUTION
Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
must be provided.
IMPORTANT
Read these instructions carefully so as to familiarise yourself with the appliance before ting the appliance to a gas cylinder.
Retain these instructions for future reference.
GB
1. General
This appliance complies with BS EN498:2012 and SANS 1539:2012
This appliance may only be used with an approved hose and regulator (A 2.8kPa hose and regulator supplied with this unit in South
Africa)
The gas cylinder is to be used in the upright position.
Only to be used with a gas cylinder that does not exceed 500mm in height(Regulator is included) and 400 mm in width.
Gas appliances require ventilation for efcient performance and to ensure the safety of users and other persons in close proximity.
Warning: Accessible parts may be very hot. Keep young children away.
After use, turn off the gas supply at the cylinder, and then at the control knobs.
When using a pot, the minimum recommended pot size is 150mm and maximum recommended size is 300mm.
Use outdoors only!
Gas Supply Sources
An approved hose and regulator connected to a rellable gas container not exceeding 9kg and
complying with local regulation in force
Country of Use
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, LT, LU, LV, PT,
SK & SI
PL
BE, CY, DK, EE, FR, FI, HU,
IT, LT, NL, NO, SE, SI, SK, RO,
HR, TR, BG, IS,LU, MT, & ZA
Appliance Catagories I
3B/P (30)
I
3+(28-30/37)
I
3B/P (37)
Allowable gasses
Butane @ 28-30mBar
Propane @ 28-30mBar
Butane/Propane mixtures
@ 28-30mBar
(South Africa 2.8kPa)
Butane @ 28-30mBar
Propane @ 37mBar
Butane @ 37mBar
Propane @ 37mBar
Butane/Propane mixtures
@ 37mBar
Main 3 Burner BBQ Unit
Jet Number 0.92
Nominal Usage
Butane - 233 g/h
per burner
Butane - 233 g/h
per burner
Butane - 276 g/h
per burner
Gross nom. heat input
3.2 kW per burner
(3.2 kW x 3 = 9.6 kW in total)
3.2 kW per burner
(3.2 kW x 3 = 9.6 kW in total)
3.8 kW per burner
(3.8 kW x 3 = 11.4 kW in total)
Side Burner
Jet Number 0.84
Nominal Usage Butane - 211 g/h Butane - 211 g/h Butane - 226 g/h
Gross nom. heat input 2.9 kW 2.9 kW 3.1 kW
Country Name and Abbreviations
AE = United Arab Emirates AL = Albania AT = Austria BE = Belgium CH = Switzerland
CZ = Czech Republic DE = Germany DK = Denmark ES = Spain FI = Finland
FR = France GB = United Kingdom GR = Greece HR = Croatia IT = Italy
JP = Japan KR = Korea NL = Netherlands NO = Norway PL = Poland
PT = Portugal RO = Romania RU = Russia RS = Serbia SI = Slovenia
SK = Slovakia SE = Sweden TR = Turkey ZA = South Africa
For gas category I3B/P(30) & I3+(28-30/37)
Woody Meridian 3 with side burner, 98510, total heat input: 12.5kW/Butane 910g/h
For gas category I3B/P(37)
Woody Meridian 3 with side burner, 98510, total heat input: 14.5kW/Butane 1055g/h
503-0630 LEV7 - (20163) Meridian 3 Woody - User Manual (EU & SA).indd 1 20/12/2016 11:09:46
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadac 20163 - Meridian Woody at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadac 20163 - Meridian Woody in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadac 20163 - Meridian Woody

Cadac 20163 - Meridian Woody User Manual - German - 6 pages

Cadac 20163 - Meridian Woody User Manual - Dutch - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info