TRSE 10
English | 2
Structure
Figure
Clear button
Quitting the programming mode
On / Enter button
Readiness for opening
LED goes on when a valid opening code is entered and programming
is successful.
Battery replacement symbol
When this LED is on, please replace all 3 batteries
(LR6 / AA / 1.5V / Alkaline).
Readiness for entry / programming
The LED goes on when the programming mode is entered. It goes o when
the programming mode is exited again.
Rejected entry / blocking time
The LED goes on when an invalid code is entered or when the programming
is incorrect. In case a wrong code is entered three times in a row, the lock is
blocked for 5 minutes. During this time, the LED ashes. In this status, opening
is not possible, even with a correct opening code.
Dear customer,
Thank you for deciding for a safe with the BURG-WÄCHTER TRSE10 electronics.
This electronics is certied according to VdS class 1 and opening is possible both
with ngerprint and using a Pincode. You have thus acquired a product meeting
extremely high security requirements and developed and manufactured using the
latest technical potential.
Important: Please read the entire User Manual before programming
and store this User Manual at a safe place for future reference at any time
you may need it.
We hope you will enjoy your BURG-WÄCHTER safe.
Your BURG-WÄCHTER KG
Important remarks
In order to enhance the protection against intrusion, the following points
should be observed:
No personal data (e. g. dates of birth) or other data, for which a link can be
derived from the code owner, should be used for coding.
If the code is stored in writing, such document should be consistently stored
safely, so that it is accessible only to the authorized persons.
Attention: Any changes of the Pincode shall be made with the safe
door opened!
When the locking system has been reset to another code, this new code should
be repeatedly used with the safe door opened.
Generally
A Pincode and 10 memory slots for ngerprints are available for opening.
Pincode: 123456 (factory setting)
The Pincode has always 6 digits.
For ngerprint opening, two dierent ngers need to be used, which have to be
dragged over the sensor successively.
When an action has been successfully completed, the green LED goes on.
Technical data
Number of Pincodes 1
Number of
ngerprints
10
Blocking times When a wrong code is entered 3 times, 5 minutes,
subsequently 10 minutes after each wrong entry
Power supply 3 x MIGNON LR6 / AA / ALKALINE
Permissible ambient
conditions
- 15 °C through +50 °C
Up to 95 % rel. air humidity (non condensing)
Menu structure
The individual labels on the keypad indicate numerals and letters. Combinations
of numerals and / or letters are used to program the individual functions. The initial
letters of a programming procedure are composed as a combination of numbers
(to facilitate their remembering). When using these explicit combinations,
the individual submenus are opened.
Opening with Pincode
Press „On / Enter, the yellow LED of the Readiness for entry / programming
icon goes on.
Enter the Pincode. The green LED goes on when entered correctly, the red one
when the entry is rejected.
Turn the rotary handle clockwise to open the door.
Opening with nger
Press „On / Enter, the yellow LED of the Readiness for entry / programming
icon goes on.
Move your 1st nger over the sensor.
The yellow LED goes o, the green LED goes briey on when the nger is
accepted, then the yellow LED goes on again.
Move your 2nd nger over the sensor.
The yellow LED goes o, the green LED goes briey on when the nger is
accepted.
Turn the rotary handle clockwise in order to open the door.
bat
Access to the programming mode to change
the lock settings
Press „On / Enter, the yellow LED of the Readiness for entry/programming
icon goes on.
Type numbers 76 (program mode), the yellow LED goes o.
Press „On / Enter“ and enter the valid Pincode.
When a valid Pincode has been entered, the green LED goes on briey,
subsequently the yellow LED ashes. As long as the yellow „Readiness for
entry / programming“ LED is ashing, you are in the programming mode and
so you can perform various actions.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Burg-Wachter TRSE 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Burg-Wachter TRSE 10 in the language / languages: English as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Burg-Wachter TRSE 10

Burg-Wachter TRSE 10 User Manual - German - 3 pages

Burg-Wachter TRSE 10 User Manual - Dutch - 3 pages

Burg-Wachter TRSE 10 User Manual - French - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info