628121
2
Zoom out
Zoom in
Previous page
1/2
Next page
Always Ask For
2
S Keep Filter Clean
A clogged or improperly installed air filter on your indoor unit will
increase operating costs and shorten the life of the unit. For
detailed filter cleaning information refer to indoor unit literature.
S Do Not Block Floor, Wall or Ceiling Vents
When drapes, furniture, toys or other common household items
block vents, the restricted airflow lessens the system’s efficiency
and life span.
S Do Not Cover or Block Outdoor Unit
The outdoor unit needs unrestricted airflow. Do not cover it or
place items on or next to it. Do not allow grass clippings, leaves, or
other debris to accumulate on the sides or top of the unit. And,
maintain a 12” (304.8 mm) minimum clearance between the
outdoor unit and tall grass, vines, shrubs, etc.
S Check Condensate Drain
Your air conditioner removes humidity from your home during the
cooling season. After a few minutes of operation, water should
trickle from the condensate drain of the indoor coil. Check this
occasionally to be sure the drain system is not clogged. Drainage
will be limited if you live in a very dry environment.
S Do Not Operate Below 55°F/12.78°C
Your outdoor unit is not designed to operate when outdoor
temperatures are lower than 55_F/12.78_C without modification.
If operation below this temperature is required, consult your Bryant
dealer.
S Coil Cleaning
Your indoor coil is located in a sealed cabinet on your indoor unit
and will require minimal cleaning with routine filter maintenance.
Longer operating cycles and reduced energy efficiency may
indicate the need for a coil cleaning by your Bryant dealer.
S Base Pan Drainage
Periodically check for and remove debris that has settled around
the base of your outdoor unit. This will ensure proper drainage of
the base pan and eliminate standing water inside the outdoor unit.
S Level Installation
Your Bryant dealer will install the outdoor unit in a level position.
If the support base settles or shifts and the unit is no longer level,
be sure to re--level it promptly to assure proper drainage. If you
notice water or ice collecting beneath the unit, arrange for it to be
drained away from the unit.
SEA COAST COIL MAINTENANCE
Coastal locations often require additional maintenance of the
outdoor unit due to highly corrosive airborne ocean salt. Although
your new Bryant system is made of galvanized metal and is
protected by top--grade paint, take the additional precaution of
periodically washing all exposed surfaces and the outdoor coil
approximately every 3 months. Consult your installing Bryant
dealer for proper cleaning intervals and procedures for your
geographic area or ask about a service contract for regularly
scheduled professional cleaning and inspections.
TROUBLESHOOTING
Before you request dealer service, check for these easily solved
problems:
S Check the indoor and outdoor disconnect switches Also check
your main electrical panel circuit breakers or fuses.
S Check for sufficient airflow. Air filter(s) should be reasonably
clean and interior vents should be open and unobstructed.
S Check thermostat settings. For cooling, your desired
temperature setting should be LOWER than the displayed
room temperature, and the System/Mode control should be on
Cool or Auto. For heating, your temperature setting should be
HIGHER than the displayed room temperature, and the
System/Mode control is set to Heat or Auto.
S Time delays - depending on the Bryant air conditioner you
have, there may be delays in unit operation that are built-in to
protect the equipment and your comfort. Don't be alarmed if
you notice a time delay in operation. It may be a standard
protection feature of your equipment. Check with your Bryant
Dealer for more information on time delays.
If you need to contact your Bryant dealer for troubleshooting
and/or repairs, be sure to have the model and serial numbers of
your equipment available (there are spaces on the cover for you to
write this information). With this information, your dealer may be
able to offer helpful suggestions over the phone or save valuable
time through knowledgeable preparation for the service call.
REGULAR DEALER MAINTENANCE
In addition to the routine maintenance that you perform, your
home comfort system should be inspected regularly by a properly
trained service technician. Many dealers offer this service at a
reduced rate with a service contract. Some service contracts offer
additional benefits such as parts discounts and no additional charge
for ”after hours or emergency service.
Your annual system inspection should include:
S Routine inspection of air filter(s) with replacement or cleaning
as required
S Inspection and cleaning of the blower wheel housing and
motor
S Inspection and, if required, cleaning of indoor and outdoor
coils
S Inspection of the indoor coil drain pan, as well as the primary
and secondary drain lines. If the system has an auxiliary drain
pan and line, they should be inspected at this time as well.
Service should include cleaning if required.
S Check all electrical wiring and connections
S Check for secure physical connections of individual parts in
each unit
S Operational check of the air conditioning system to determine
actual working condition. Necessary repair and, or adjustment
should be performed at this time.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
E2007 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 11/07
R e p l a c e s: O M 0 1 --- 2 4
Catalog No. OM01---25
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bryant Legacy 113A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bryant Legacy 113A in the language / languages: English as an attachment in your email.

The manual is 0,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info