Solar storage cylinder is cooling rapidly.
High heat loss. Cylinder insulation is faulty or not correctly fitted. Check insulation. Insulate the cylinder connection points.
Controller setting for backup heating is not correct.
Check settings of boiler controller.
Single-pipe circulation (micro-circulation in the pipelines).
Install a "U" bend in the pipe to prevent heat convection.
Gravity circulation via collector array or DHW recirculation line
or backup heating.
Check gravity brakes.
Hot water recirculation running too frequently and/or at night.
Check programmed on/off times and cyclic mode.
When sun is shining on collectors, the collector glass is fogged for a long period of time.
Condensate in the
collector.
Insufficient ventilation of the collector (in the case of ventilated
collectors).
Clean ventilation openings.
System performance is falling.
Solar yield too low. Collectors are under shade. Remove shade.
Air in the system.
Bleed or purge the system.
Pump is running at decreased power.
Check the pump.
Heat exchanger dirty/calcified.
Wash/decalcify the heat exchanger.
Collector glazing is very dirty.
Clean the collector glazing with a glass-cleaning agent (no acetone).
Backup heating is running despite good solar exposure.
Solar yield too low. Storage cylinder temperature sensor for backup heating is
faulty or incorrectly positioned.
Check cylinder temperature sensor position, mounting and
characteristics.
DHW recirculation is incorrectly connected or switched on for
too long.
Check DHW circulation connection; if necessary, reduce switch-on
time for recirculation.
Backup heating temperature set too high. Check settings.
Air in the system.
Bleed or purge the system.
Controller faulty.
Check controller, replace if necessary.
Type of fault
Effect Possible causes Remedy
Table 17
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AGS50-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AGS50-2 in the language / languages: English as an attachment in your email.

The manual is 2,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info