SAFETY INSTRUCTIONS
The appliance is designed for clean water with a temperature of max. 50°C:
any other use should be avoided.
When the maximum pump pressure is reached, the unit switches off the pump.
However, there must be a pressure difference of at least 1.4 bar between
switching on and off.
Children from the age of 8 years, people with mental, sensory or physical
impairments may only use the unit if they have been thoroughly familiarised
with the functions and safety precautions by a responsible supervisor and
understand the risks involved.
Assembly
Make sure that the system is installed ood-proof and sufciently cooled
with dry air.
If the pump is mounted directly in the distribution network, it must be
ensured that the inlet pressure is added to the pump pressure and that the
total pressure does not exceed 10 bar.
The unit can be installed in an existing pipe / plant, provided that the
minimum water requirement of the pump is always covered. Observe the
installation diagrams.
Electrical connection
Nominal current consumption of the pump must not exceed 10 (A) and the
maximum power of the motor must not exceed 1.8 kW. A disconnecting
device must be provided in the electrical installation, which allows
disconnection from the mains with at least 3 mm contact opening for
each pole. Pumps in alternating current design have an integrated motor
protection switch. Pumps in three-phase design must be installed by
the customer with an adjusted motor protection switch. We accept no
liability for the consequences of improper installation, commissioning and
improper electrical installation.
The power cable must correspond to type H08 RN-F according to DIN
VDE0620.
This diagram facilitates a correct mains connection.
The system is secured by a differential switch (1 fn=30 mA)
The power cable of the pump must at least correspond to H07 RN-R
according to DIN VDE 0620 and be provided with cable lugs. The
connection of the pump must be carried out by a qualied electrician.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Blumfeldt 10034756 Liquidflow 800 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Blumfeldt 10034756 Liquidflow 800 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 0.37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info