Wireless Carbon Monoxide Detector (CO-S1)
P
P
a
a
r
r
t
t
s
s
D
D
e
e
s
s
c
c
r
r
i
i
p
p
t
t
i
i
o
o
n
n
1. Dual Color LED Indicator (Amber & Red)
2. Learn/Test Button
Press the button to transmit a learn/test code or silence the alarm
P
P
a
a
c
c
k
k
a
a
g
g
e
e
C
C
o
o
n
n
t
t
e
e
n
n
t
t
1 x CO Detector
1 x Mounting Bracket
2 x wall plugs and screws
3 x AA 1.5V alkaline batteries
Put the Control Panel into learning mode, then press the Learn
button to transmit learn code. Refer to Control Panel manual to
complete the learning process.
M
M
o
o
u
u
n
n
t
t
i
i
n
n
g
g
Use the mounting bracket included in the package to mount the
CO detector on the wall.
1. Use the two holes on the mounting bracket as template, drill
two holes on the wall.
2. Insert wall plug if fixing into plaster or brick
3. Screw the bracket onto the wall.
4. Hook the CO detector onto the mounting bracket.
C
C
a
a
r
r
b
b
o
o
n
n
M
M
o
o
n
n
o
o
x
x
i
i
d
d
e
e
D
D
e
e
t
t
e
e
c
c
t
t
i
i
o
o
n
n
Upon CO detection, the CO Detector will raise alarm with its
built-in siren and send alarm signal to Control Panel in different
time length according to the CO concentration level detected.
Please see following table for reference.
Once the CO Detector has activated the alarm, it will continue to
resend the alarm signal every 10 minutes until the CO
concentration level drops below 30 ppm. The CO Detector will
then send a restoration signal and stop the alarm. You can also
press the learn/test button to silence the alarm manually. The CO
Detector will then enter Alarm Silence mode.
Alarm Silence
When the alarm is activated, pressing the learn/test button will
put the CO Detector into Alarm Silence mode for 10 minutes.
During this period, the built-in siren will be silenced and the
Amber LED will flash once per second.
After the 10-minute period is over, the CO Detector will check the
CO concentration again. If the CO concentration is still over
alarm threshold, the CO Detector will sound the alarm and
transmit alarm signal again. If not, it returns to normal operation.
B
B
a
a
t
t
t
t
e
e
r
r
y
y
The CO detector uses three AA 1.5V alkaline batteries as its
power source. It features low battery detection function to notify
the Control Panel when battery voltage is low.
Follow the procedure below to change the batteries.
1. Loosen the screw on the back to open battery compartment
cover.
2. Remove the old batteries.
3. Press the learn/test button several times to fully discharge.
4. Insert the new batteries observing correct polarity. The CO
detector will sound 2 short beeps, RED LED will flash once
5. Replace the battery cover and tighten the screw.
L
L
E
E
D
D
I
I
n
n
d
d
i
i
c
c
a
a
t
t
o
o
r
r
Off Normal Operation
Amber LED flashes
every 30 seconds
Low Battery
Amber LED flashes
quickly
CO Sensor fault
Red LED flash CO Detector is alarming
Red LED on CO Detector is transmitting signal
E
E
n
n
v
v
i
i
r
r
o
o
n
n
m
m
e
e
n
n
t
t
a
a
l
l
C
C
o
o
n
n
d
d
i
i
t
t
i
i
o
o
n
n
-10°C to 40°C, relative humidity 85% non-condensing.
R
R
a
a
d
d
i
i
o
o
433 MHz
CO concentration
level
Time taken before
alarming
30 ppm None
50 ppm 60~90 minutes
100 ppm 10~40 minutes
300 ppm Under 3 minutes
L
L
e
e
a
a
r
r
n
n
i
i
n
n
g
g
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
1
2
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
Mounting
Holes
Mounting Bracket
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Blaupunkt CO-S1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Blaupunkt CO-S1 in the language / languages: English as an attachment in your email.

The manual is 0,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Blaupunkt CO-S1

Blaupunkt CO-S1 User Manual - German - 2 pages

Blaupunkt CO-S1 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info