The gauge is intended as a guide only. Tyre pressures
should be regularly checked with a certified gauge.
Before use, check the power supply cord for signs of
damage, ageing and wear.
Do not use the appliance if the power supply cord or
mains plug is damaged or defective (where applicable).
Electrical safety
Electrical safety can be further improved by using a high
sensitivity (30mA / 30mS) Residual Current Device (RCD).
If the supply cord is damaged, it must be replaced by the
manufacturer or an authorised Black & Decker Service
Centre in order to avoid a hazard.
The following warning symbols are found on the tool/
appliance:
Features
1. Storage compartment cover
2. Pressure gauge
3. Air hose with universal valve adaptor
4. 12 Volt dc cord and adaptor
5. 230 Volt ac cord and plug
Residual risks
Additional residual risks may arise when using the tool which
may not be included in the enclosed safety warnings. These
risks can arise from misuse, prolonged use etc.
Even with the application of the relevant safety regulations
and the implementation of safety devices, certain residual
risks cannot be avoided. These include:
Injuries caused by touching any rotating/moving parts.
Injuries caused when changing any parts, blades or
accessories.
Injuries caused by prolonged use of a tool. When using
any tool for prolonged periods make sure you take
regular breaks.
Impairment of hearing.
Health hazards caused by breathing dust developed
when using your tool (example:- working with wood,
especially oak, beech and MDF).
Use
Air hose and cord storage
The air hose (3) and the ac cord (5) are stored in the storage
compartment (1) on top of the Inflator (fig. A). The holes in
both sides of the cover (1) allow for the hose and cord to exit
from the compartment so that the compartment cover can be
closed while the Inflator is in use. The dc cord (4) is stored in
the storage compartment (9) (fig. D) at the rear of the inflator.
Fitting the accessories (fig. B & D)
Your inflator is supplied with the standard tapered nozzles
and the needle inflator nozzle (6), these are located on the
base of the unit (fig. D).
To use the universal valve adaptor, make sure that the
lever is in the up position.
Place the valve adapter over the stem of the inflation
needle or tapered nozzle (fig. B).
Press the lever on the valve adapter down to lock it in
place.
Place the inflation needle or tapered nozzle into the item
to be inflated.
Note: Always make sure that the lever is in the up position
when not in use.
Operate your Inflator only with the universal valve adaptor or
with the included nozzles.
Note: Make sure that the universal valve adaptor is firmly
locked in place before turning the Inflator on.
Many inflatables have an internal flap that prevents air loss
during inflation. Unless this flap is displaced by the nozzle
the inflatable will not inflate. Push the nozzle firmly into the
valve to make sure that you push this flap out of the way.
Store the inflation needle inside one of the tapered nozzles
and snap the tapered nozzles into the storage slots located
on the bottom of the Inflator (fig. D).
Warning! Excessive air pressure may cause a hazardous
risk of bursting or personal injury. Check the manufacturer's
maximum pressure rating for the items being inflated.
Note: If the pressure rating for the item being inflated is
above 100 psi, note that the maximum run time is 10
minutes, leave to rest for 20 minutes before re-use.
This tool/appliance is double insulated; therefore no
earth wire is required. Always check that the power
supply corresponds to the voltage on the rating
plate.
Read the instruction manual before using the
inflator.
Do not expose the appliance to rain or high
humidity.
Before performing maintenance or cleaning
on the appliance, unplug the supply cord.
Do not leave the inflator unattended.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Black Decker ASI300 T3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Black Decker ASI300 T3 in the language / languages: English as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Black Decker ASI300 T3

Black Decker ASI300 T3 User Manual - English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info