36 Beurer GL40 mmol/L
EMC
This unit complies with European standard EN 61326 and is subject to specific safety
precautions in terms of electromagnetic compatibility. Note that portable and mobile RF
communication equipment can affect this unit. Further details can be requested by con-
tacting the customer service address provided below.
Note regarding function of test strips
The test strips enable a quantitative measurement of the glucose content of capillary
whole blood. When the slit for collecting blood comes into contact with a drop of blood, it
fills automatically through simple capillary action. The blood is sucked into the absorbing
slit of the test strip and the measuring device measures the sugar level of the blood.
The test is based on the measurement of an electric current caused by a chemical reac-
tion between the glucose and the test strip reagent. The measuring device analyses this
current. The flow of current depends on the glucose content of the blood sample. The
results are shown in the display of the measuring device. Only a small quantity of blood is
required (0.6 microlitres) and the measurement takes approx. five seconds. The test
strips can detect blood sugar levels in the range 1,1 to 33,3 mmol/L.
Chemical components of the test strip sensor
Glucose oxidase 0.6 IU
Electron shuttle 0.03 mg
Non-reactive components 0.06 mg
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer GL40 mmol-L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer GL40 mmol-L in the language / languages: English as an attachment in your email.

The manual is 2,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer GL40 mmol-L

Beurer GL40 mmol-L User Manual - German - 40 pages

Beurer GL40 mmol-L User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info