612640
4
Zoom out
Zoom in
Previous page
1/24
Next page
The installation of the appliance must be carried out according to the norms in force of the country
concerned and the appliance must be installed in a well ventilated place.
This appliance is not equipped with devices to remove the products of combustion. The appliance
must therefore be connected following the norms for installation mentioned above. Special attention
must be paid to the information below regarding aeration and ventilation of the premises.
VENTILATION OF THE PREMISES
To guarantee that the appliance works correctly it is necessary that the place where the appliance is installed
is continuously ventilated. The volume of the premises must not be less than 25 m³ and the quantity of air
needed must be based on the regular combustion of gas and on the ventilation of the premises. The natural
flow of air will take place through permanent openings made in the wall of the premises to be ventilated:
these openings will be connected to the outside and must have a minimum section of 100 cm² ( see Fig. 4 ).
These openings must be made in such a way that they cannot be obstructed.
POSITION AND VENTILATION
The cooking appliances that use gas must always remove the products of combustion via a hood linked to
chimneys, chimney flues or via a direct connection to the outside ( see Fig. 5A ). If it is not possible to fit a
hood it is possible to use a fan, fitted on the window or facing directly outside, which operates when the
appliance is in use. ( see Fig. 5B ). In this way the norms in force of the country concerned regarding the
ventilation of premises are strictly followed.
CONNECTING THE APPLIANCE TO THE GAS SUPPLY
Before connecting the appliance to the gas supply you first need to remove the plastic protective
plug for the gas supply which is inserted under pressure in the gas inlet connection. To remove the
plug simply unscrew it.
Then make sure that the details shown on the label on the lower part of the case are compatible with
those of the gas supply.
A label on the last page of this manual and on the lower part of the case indicates the conditions for
regulating the appliance: type of gas and pressure used.
IMPORTANT: This appliance must be installed in accordance with the norms in force of the country
concerned and it must only be used in a well-ventilated place.
ATTENTION: Remember that the gas inlet connection for the appliance is threaded 1/2 gas
cylindrical male in accordance with the norms UNI-ISO 228-1. (Fig. 6-7)
CONNECTION OF THE APPLIANCE TO THE ELECTRICITY SUPPLY:
Connection to the electricity supply must be carried out according to the norms and indications of
the law in force.
Before carrying out the connection check that:
- The electric charge of the system and the sockets are suitable for the maximum power of the appliance (
see label on the lower part of the case ).
- The socket or system is equipped with an efficient earth connection according to the norms and indications
of the law currently in force. No responsibility can be held if these indications are not respected.
When the connection to the electricity supply is made with a socket.
Fit onto the electric cable a standard plug ( if it is not provided ) which is appropriate for the charge indicated
on the label. Connect up the wires according to the diagram in Fig. 8 taking care to respect the
corresponding pairs listed below:
letter L (phase) = brown coloured wire;
letter N (neutral) = blue coloured wire;
symbol” earth = green-yellow coloured wire;
- The electric cable must be positioned so that it cannot reach a temperature of over 75 K at any point.
- Do not use reducers, adapters or shunts for the connection as they could cause false contacts and
subsequent dangerous overheating.
When the connection is made directly with the electricity supply:
- To connect the appliance directly to the supply mains, a means for disconnection having a contact
separation in all poles that provide full disconnection under overvoltage category III conditions, must be
incorporated in the fixing wiring, according with the wiring rules.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bertazzoni PM6040X PM6V B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bertazzoni PM6040X PM6V B in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info