What should I do when the automatic safety system detects a malfunction?
The programme is interrupted and various indicators (depending on model) point to the source of the
fault.
Fault description table.
a.Water inlet fault (no or
insufficient water supply)
The display alternately shows
“FH”. Switch off the appliance
by turning the programme
selector to the “ ” position
and unplug it.
Check whether:
the tap is fully turned on and
the water supply pressure is
sufficient;
the water inlet hose is kinked;
the mesh filter in the water
inlet hose is blocked (see “Care
and Maintenance”);
the water in the water inlet
hose is frozen.
the appliance has a safety hose
and the safety valve is open
(red indicator in the safety
valve inspection window).
In this case replace it with a
new safety hose.
Reconnect the appliance.
Reselect the desired
programme and press the
“Start/Pause”
button to
restart the programme.
If the fault re-occurs, contact
the After-Sales (see “After-
Sales Service”).
b.Draining out fault
The display alternately shows
“FP”. Switch the appliance off
by turning the programme
selector to the “ ” position
and unplug it.
Check whether:
the drain hose is kinked (see
“Installation”);
the pump impeller is
obstructed (see “Cleaning the
Foreign Body Trap”).
the water in the drain hose is
frozen.
if water has remained in the
drum, you can drain it by
following the instructions in
the chapter “Draining Residual
Water”.
IMPORTANT
: Before draining,
allow the wash water to cool
down.
Reconnect the appliance.
Reselect the desired
programme and press the
“Start/Pause”
button to
restart the programme.
If the fault re-occurs, contact
After-Sales Service (see “After-
Sales Service”).
c. Electrical module fault
The display shows “F4” to
“F15”.
Select a programme and press
the
“Start/Pause”
button
again.
If the fault re-occurs, contact
After-Sales Service (see “After-
Sales Service”).
d.Water Stop fault
(depending on model)
An audible signal sounds and
the pump operates. The light
of the Water Stop indication is
on or the display shows “FA”.
Switch the appliance off by
turning the programme
selector to the “ ” position,
unplug the appliance and turn
off the water tap.
The “Water Stop” fault may
have been triggered by:
1.too much foam.
2.
a leak in the inlet hose or in the
appliance.
Tilt the appliance forwards
carefully to allow the water to
drain out.
Then:
1.reconnect the appliance,
2.
turn on water supply (if
“Start/Pause”
button is not
pressed, but the machine
begins to fill, turn off the
water supply tap and contact
After-Sales Service),
3.
reselect the desired
programme and press the
“Start/Pause”
button.
If the fault occurs again,
contact After-Sales Service
(see “After-Sales Service”).
The pilot lamp goes on. Fault description
“Water tap” “Water inlet fault”
- “Draining fault”
- “Electrical components fault”
“Water Stop” Water Stop fault
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bauknecht wats 5550 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bauknecht wats 5550 in the language / languages: English as an attachment in your email.

The manual is 0,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bauknecht wats 5550

Bauknecht wats 5550 Quick start guide - German - 2 pages

Bauknecht wats 5550 User Manual - German - 19 pages

Bauknecht wats 5550 Quick start guide - Dutch - 2 pages

Bauknecht wats 5550 User Manual - Dutch - 2 pages

Bauknecht wats 5550 Quick start guide - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info