5. ERRORS AND MAINTANACE
Maintenance and repair of the heater should only be performed by personnel trained
and qualified by AUTOTERM.
ERROR MESSAGE FAULT CODE BY HEATER
AIR HEATERS FLOW 5 / Flow 14D v2 FLOW 14D
Air Ducting or
Outlet! 1;2 -
Service! 4; 5; 6; 9; 10; 13; 16; 27; 28
7; 11; 29; 32; 34; 36; 37 3; 24; 25; 26; 3
Overvoltage! 12
Undervoltage! 15
Low voltage! 35 -
Fuel pump! 17 17; 22 17
No connection! 20; 30 20; 30; 50 20
Overheating! 31 1 1; 2
Heater Locked! 33 37 -
Check fuel system! 8; 78 29; 78
Coolant
pump/circuit! - 14
If the water temperature reaches 80 degrees, the heater will shut down and
an error message will appear.
In case of an error LED indicators blink red once every 5 seconds and an error
message is displayed depending on the fault and the heater connected. Full
descriptions of the fault codes can be found in the respective manual of the
heater.
REMINDER!
To ensure reliable operation of the heater, it is required to start it once in 30 days on
max heating power for 30 minutes including the warm seasons of the year, when heater
is out of operation.
This action is necessary to remove any viscous film sediments on moving parts of the
fuel pump. Failure to do so may lead to premature failure of the heater.
That is why AUTOTERM Comfort Boiler Control has a built-in reminder to
start the heater for 30 minutes if it has been out of operation for at least
30 days. After 30 days of inactivity since the last start red LED indicators
blink once in every 5 seconds and message is displayed.
Accept the start by pressing the knob once. Decline the start by pressing the “Back” button
once. In case of a decline, this message is repeated if the heater hasn’t been launched in any
of the heating modes.
15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Autoterm Comfort Boiler Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Autoterm Comfort Boiler Control in the language / languages: English as an attachment in your email.

The manual is 1.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info