The product you have just purchased has undergone numerous tests and inspections to guarantee the highest quality. We hope it will give you entire
satisfaction.
INSTALLATION OF THE PANEL HEATER
Please read the instructions before starting to install the heater. Disconnect
the power before carrying out any work on the heater. Keep these
instructions even once you have installed your heater.
1) Where to install your heater ?
- This equipment was designed to be installed in a residence. Please ask your
distributor before using it for any other purpose.
-
The panel heater should be installed according to normal trade practice and in
compliance with legislation in the relevant country (the IEE Wiring Regulations).
- The equipment is class 2 and is protected against splashed water IP
24. The device is to be installed so that switches and other controls cannot
be touched by a person in the bath or shower, except in the UK where IEE
Regulations 701.512.2 and 701.512.3 apply. These allow the use of IP24
rated products and their integral controls in Zone 2 and outside zones.
a
- Comply with the minimum clearance distances for positioning of the panel
heater.
b
- If your wall covering is laid on foam, a spacer the same thickness as the
foam must be placed under the panel heater’s support. This ensures there is
free space behind the panel heater to make sure its control settings are not
adversely affected.
- Do not install the panel heater:
c In a draught that might affect adjustment (for example, under a
central mechanical ventilation unit etc...).
c Under a xed mains power socket.
c In zone 1 of bathrooms a.
It is forbiden to install vertical product in horizontal position.
2) How to install the panel heater ?
2-1) Release the appliance’s hook-on bracket
We recommend that you place the radiant panel at, face down.
Have a straight head screwdriver to hand.
2-2) Fix the hook-on bracket
Use the wall-mounting bracket as a template for positioning the heater.
Drilling points A
Drilling points B
2-3) Connecting the panel heater
- The appliance should have a 230-240V 50Hz power supply.
- The panel heater must be connected to the mains, either by a 3-wire cable
(Brown= Phase, Blue = Neutral, Black = Pilot wire) by means of a connexion
box.
In humid areas such as bathrooms and kitchens the power socket must be
installed at least 25 cm above the oor.
- The installation should be tted with a double pole break device with a break
of at least 3 mm.
- Connection to earth is prohibited. Do not connect the pilot wire
(black) to earth.
- The heater must be installed by a qualied electrician in accordance with
the local regulations. The heater and the pilot wire (black) must NOT be
connected to earth. If the power cable is damaged, it must be replaced by
the manufacturer or its after-sales service Department or a similary qualied
person to avoid any risk.
If a pilot or piloted panel heater is protected by 30mA differential (e.g.
bathroom) the pilot wire’s power must be protected on this differential
Commands
Received
No current
Complete
altermation
230 V
Négative
Half/altermation
- 115 V
Positive
Half/altermation
+ 115 V
Oscilloscope
Réf/Neutral
Mode
obtained
COMFORT ECO
ANTI-
FREEZE
STOP
HEATING –
LOAD
SHEDDING
2-4) Lock the appliance on the hook-on bracket f
USING THE PANEL HEATER
1) Description of the control unit :
1
g
switch .
2
g
Temperature adjustment control knob.
V1
g
Heating indicator light
2) Fixing the comfort temperature
The comfort temperature is the temperature that you would like while the
room is occupied.
a) Put the 1 switch to
.
b) A
just the control knob
2
to the wished position, the heating indicator V1
comes on if the room temperature is below the required temperature.
c) Wait a few hours for the temperature to stabilise.
d) If the setting is satisfactory (if necessary use a thermometer to check),
mark the position for future use.
e) If the setting is not satisfactory, adjust it and start again from point c.
3) Fixing the Eco temperature :
This is the required temperature during periods when the room is
unoccupied. It is recommended that this mode should be used if the room is
unoccupied for more than 2 hours.
a) Set the cursor 1 switch knob to
.
b) Ajust the control knob 2 to the wished position, the heating light V1
comes on, if the ambient temperature is lower than the instruction of desired
Eco temperature.
c) Wait a few hours until the temperature stabilizes.
d) If the setting is satisfactory (if necessary use a thermometer to check),
mark the position.
If the setting is not satisfactory, adjust it and start again from point c.
Note : When switching n°1 (on the picture) is set on Programming system
(clock symbol) with the PassProgram On/Off, please refer to paragraph n°8.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atlantic F117 ODYSSEE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atlantic F117 ODYSSEE in the language / languages: English, German, Dutch, French, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 4,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info