Ventilation
The electronics in the appliance require cooling. The ventilation
openings are located on the underside of the appliance. It must be
possible for cool air to be drawn in through these openings. The
appliance is fitted with outlet openings at the front and bottom. The
kitchen unit will require a few modifications to allow optimum cooling
of the hob.
Above drawer or fixed panel
Saw out the ventilation openings (min. 100 cm
2
). Ventilation is via plinth
and rear of cupboard.
Do not allow the ventilation openings on the underside of the appliance
to be blocked by a drawer. Where there is a drawer, a gap of at least
560 x 3 mm should be made at the front. The distance between drawer A
and the hob should be a minimum of 10 mm.
building in INSTALLATION
150
A
min.
560 x 3 mm
min.
10 mm
130
INSTALLATION building in
Cut opening in worktop
Saw the opening in the worktop. This should be done very accurately
(see table). Also saw out any partitions that may be present. The distance
from the saw line to the rear wall and/or side wall is indicated in the
table.
Table
Space to be left free around the appliance
602
522
48
560
490
min.50
min. 600 mm
min. 650 mm
min. 450 mm
min. 40 mm
cooker hood
cabinet
side wall
hob
min. 40 mm
Type of hob
HI6171T
Appliance width x depth
602 x 522 mm
Installation height from top of worktop
48 mm
Cut out dimensions width x depth
560 x 490 mm
Distance from saw line to rear wall
50 mm minimum
Distance from appliance to side wall
40 mm minimum
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG HI 6171 T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG HI 6171 T in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info