702740
1
Zoom out
Zoom in
Previous page
1/16
Next page
SHATTERPRO 3 GLASSBREAK DETECTO R
INSTALLATION INSTRUCTIONS
- 1 -
Figure 1 - Mounting Locations
Figure 2 - Multiple Window Coverage
Microphone
LED
Figure 3 - Attaching the Cover
7. Connect the system wires to the appropriate screw terminals on the base
and tighten the screws.
8. Replace the cover as follows:
- Round housing: Line up the tabs on the base with the correspond-
ing tabs on the cover, press together and turn clockwise until the
cover snaps firmly into place. See Figure 3.
- Rectangle housing: Press the cover back down over the detector
until the cover snaps firmly into place.
9. Apply power. The red LED should flash once.
10. Test the detector. See Testing the Detector.
F
NL
D
I
S
DK
DESCRIPTION
The ShatterPro 3 is an acoustic glassbreak detector designed to detect
breaking glass from framed windows in the perimeter of a building. The
detector is mounted in the building interior and uses a power supply from a
12 VDC control panel. The detector is available in either a low-profile round
housing or a rectangular housing that connects easily to a single-gang box.
SELECTING A L OCATION FOR THE D ETECTOR
Mount the detector on ceilings or on walls opposite or adjacent the window
to be protected. See Figure 1. Use the following guidelines to determine the
best location to install the detector.
w Mount at least 1m from the glass windows being protected.
w Windows must be at least 30 x 60 cm square.
w Avoid locations where lined, insulating or sound deadening curtains are
used.
w Mount 30cm away from wall corners.
w Avoid locations where interior closed wooden shutters are used.
w Locate in a suitable environment as follows:
- Temperature between and 50°C
- Humidity between 10 and 90% non-condensing
w Mount the detector on a stable surface up to 7.6 m from the farthest point
on the glass surface. See Figure 1.
w Avoid locations that expose the detector to possible false alarm sources
such as: Glass airlocks and vestibule areas, kitchens, residential car
garages, small utility rooms, stairwells, bathrooms, small acoustically live
rooms, air vents.
SELECTING THE B EST L OCATION FOR M ULTIPLE W INDOW
COVERAGE
The detector has a 360° coverage pattern that can cover several windows
in a single room as follows (See Figure 2):
w Draw an imaginary line from the center of each window to be covered
in towards the center of the room.
w Mount the detector as close to where the lines intersect as possible.
w Do not mount the detector at more than a 60° angle from the center of any
window to be protected.
INSTALLING THE D ETECTOR
All wiring must conform to national approvals.
Important ! If you are unsure about a location, connect a 9 V battery to the
detector and test it before permanently mounting. See Testing the Detector.
To install the detector:
1. Run the security system wiring to the detector location.
2. Remove the front cover as follows:
- Round housing: Press the release tab on the lip of the base, twist
the cover counterclockwise, and lift off.
- Rectangle housing: Gently pry up the slot on the bottom of the
cover to unlock the cover. Lift up the cover until it latches in the open
position.
3. Set the range with J3 on the circuit board. See Setting the Range.
4. Remove the appropriate wiring and mounting knockout holes from the
base. See Figure 4.
5. Pull the wires through the knockout holes and use two screws to attach
the base to the surface. Use wall anchors if necessary.
6. Strip 1 cm of insulation from each wire.
GB
Ceiling
mount
Detector
60° max.
60° max.
7.6 m
max.
7.6 m
max.
Ceiling
mount
Wall
mount
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech SHATTERPRO 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech SHATTERPRO 3 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish as an attachment in your email.

The manual is 0,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info