44205
5
Zoom out
Zoom in
Previous page
1/8
Next page
5
PRACTICAL TIPS
- If the water is very hard, it is recommended that a water softener be added to the
system so as to reduce the formation of limescale in the boiler exchangers. This will
ensure that the efficiency of the unit remains the same over time, reducing gas
consumption and maintenance costs
.
- If the boiler should be out of use for a prolonged period, it is recommended that the
electr
ical power supply be disconnected and that the external gas cock be closed. If low
temperatures are expected, the boiler and system pipe work should be drained in order
to prevent frost damage.
- To improve comfort and take full advantage of the heat produced by the boiler, it is
recommended that an external (room) thermostat be installed.
- It is good practice to clean and service the appliance and central heating system every
year. Call an Authorised Service Centre.
IGNITION PROCEDURE
T
urn the selector knob
“A” to the
“I” position. The display will
indicate
o
o
n
n
indicating that the boiler is ready to operate. The
electronic control unit will ignite the burner, without any manual
inter
vention but in response to the request for Domestic Hot Water
or heating. If, after approximately 10 seconds, the burner has not
ignited, the boiler saf
ety devices will shut off the gas and the
display will indicate the fault code
A
A
0
0
1
1
. To reset the ignition
system, the reset b
utton
“D” m
ust be pressed and released. Should
the boiler fail to ignite a second time, check that the external gas cock
is open. If the problem persists, contact an Authorised Service Centre.
WINTER AND SUMMER OPERATING MODES
In the ‘winter’ operating mode, the boiler will produce both Central
Heating and Domestic Hot Water. In the ‘summer’ operating mode,
the boiler will produce only Domestic Hot Water.
Using the knobs on the control panel, the user can select ‘winter’
or ‘summer’ operating mode.
Keeping the knob
“C” at the “ ” position selects the ‘summer’
operating mode, the simbol “ will illuminate. ‘Winter’ operating
mode may be selected by positioning the knob “C” between the
min. and max. settings. The simbol “ will illuminate.
ADJUSTING THE HEATING
It is possib
le to set the temper
ature of the Centr
al Heating system b
y adjusting the knob
“C”.
By positioning the indicator somewhere between min. and max., a temperature may
be obtained which varies from approximately 45˚C to about 80˚C.
The w
ater temper
ature in the pr
imar
y circuit ma
y be chec
ked on the display.
EXTERNAL (ROOM) THERMOSTAT CONTROL
If an external (room) thermostat is installed, it is recommended that the temperature of
the Central Heating system be set by means of the
“C” knob, leaving it at max in order
to obtain the best performance from the boiler and to allow the regulation of the external
temperature to function efficiently.
SETTING THE HOT WATER FOR DOMESTIC USE
Both in the winter and summer mode, the temperature of the Domestic Hot Water may be
adjusted b
y using the
“B” knob
.
A deliv
er
y temper
ature f
or the water may be chosen in a
r
ange from 36˚C to about 56˚C
, depending on the flow rate of the water and the position
of the knob between the min. and max. settings.
The water temperature in the primary circuit may be checked on the display.
II II
A
PL004D
PL004D
EC EC
D
PL006C
PL007D
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
C
PL009D
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
C
estate
inverno
PL007C
summer
winter
PL009D
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
C
PL008D
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
C
1
2
3
4
5
6
B
PL008D
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston MicroGenus HE 28 MFFI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston MicroGenus HE 28 MFFI in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info