For appliances containing flammable refrigerants, the system must be flushed with OFN to make the unit safe. You
may need to repeat this process several times. Compressed air or oxygen must not be used for purging refrigerant
systems.
For appliances containing flammable refrigerants, flushing must be achieved by breaking the vacuum in the system
with OFN and continuing to fill until the operating pressure is reached, then discharging to the atmosphere and
finally lowering the vacuum. This process must be repeated until there is no more refrigerant in the system. When
the final OFN charge is used, the system must be vented to atmospheric pressure to allow the work to be carried
out. This operation is absolutely essential if you want to carry out brazing operations on the pipes.
Make sure that the vacuum pump outlet is not close to ignition sources and that ventilation is available.
Charging procedures
In addition to conventional charging procedures, the following requirements must be followed.
- Make sure that contamination of different refrigerants does not occur when using charging equipment. Hoses or
lines should be as short as possible to minimize the amount of refrigerant they contain.
- The cylinders must be kept upright.
- Make sure the refrigeration system is grounded before charging the system with refrigerant.
- Label the system when charging is complete (if not already done).
- Be very careful not to overfill the refrigeration system.
Before recharging the system, it must be pressure tested with the appropriate purge gas.
The system must undergo a leak test upon completion of the charge but prior to commissioning. A subsequent leak
test must be carried out before leaving the site.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo X3i Eco Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo X3i Eco Plus in the language / languages: English as an attachment in your email.

The manual is 3.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo X3i Eco Plus

Argo X3i Eco Plus User Manual - German - 63 pages

Argo X3i Eco Plus User Manual - French - 63 pages

Argo X3i Eco Plus User Manual - Italian - 60 pages

Argo X3i Eco Plus User Manual - Spanish - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info