Continual improvement policy
Arcam has a policy of continual improvement for its products.
This means that designs and specications are subject to
change without notice.
NOTE: All specication values are typical unless otherwise
stated.
Before returning your amplier for service, please check the
following:
Sound cuts out for no reason
If the temperature of the internal heatsink rises above a safe
level, then a thermal cutout inside the amplier will operate.
The power indicator on the front panel ashes and the
protection system temporarily removes the power to the
speakers. The system resets itself as the heatsink cools down.
With two pairs of low impedance speakers connected,
overloads are more likely. Overloading the amplier may
cause it to shut down because of overheating.
Note that because of the high output voltage from a CD
player, it is possible to drive the A90 at full power even
though the volume is not set at maximum.
Amplier does not switch back on
The A90 and P90 ampliers have a protection mechanism
which is activated if you switch the unit on immediately after
turning it off. If this mechanism activates, wait 30 seconds then
try again.
Technical specications
A90 P90
Continuous power output, per channel
Both channels, 8Ω, 20Hz–20kHz 90W 90W
Single channel, 4Ω, 1kHz 150W 150W
Distortion, 8Ω, 80% power, 1kHz 0.005% 0.005%
Inputs
Phono cartridge (optional module)
input sensitivity, MM 2.5mV
input sensitivity, MC 250µV
Line and tape inputs
Nominal sensitivity 250mV 700mV
Input impedance 22kΩ 22kΩ
Signal/noise ratio (CCIR) 105dB 112dB
Tone controls, max. boost/cut ±12dB
Preamplier outputs
Nominal output level 700mV
Output impedance <50Ω
General
Power consumption (maximum) 800VA 800VA (950VA for P90/3)
Dimensions W x D x H (including feet) 435 x 340 x 100mm 435 x 320 x 100mm
Weight (net) 9kg 9.5kg (10.5kg for P90/3)
Weight (packed) 10.5kg 11kg (12kg for P90/3)
Supplied accessories mains lead
CR-389 remote control
2 x AAA batteries
mains lead
E&OE
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arcam DiVA P90-3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arcam DiVA P90-3 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info