Average sensing RMS calibrated technical :
Most digital multimeters use an average sensing RMS calibrated
technique of an electrical average circuit to measure RMS value
of AC signals. This technique is scaling the output average
value of the average sensing circuit by the ratio of RMS value
to average value, for sine wave the ratio is 1.11. Unfortunately,
this ratio varies widely as a function of the wave form, it
will give grossly incorrect results in many cases. The table
shows a few representative examples comparing RMS to
average.
Terms In The Specification
Waveform
Type 1 Volt
Peak Ampli-
tude
Crest Fac-
tor (V
PEAK
/
V rms)
True rms
Value
Average Re-
sponding
Circuit Cali-
brated rms
Value of Sine
Waves Will
Read
% of Read-
ing Error*
Using Av-
erage Re-
sponding
Circuit
1.414 0.707V 0.707V
0%
1.00 1.00V 1.11V
+11.0%
1.73 0.577V 0.555V
-3.8%
Rectangular
Pulse Train
2
10
0.5V
0.1V
0.278V
0.011V
-44%
-89%
* % of Reading Error =
Average Responding Value - True rms Value
True rms Value
x 100%
V
Peak
V
Peak
V
Peak
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Appa 73 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Appa 73 in the language / languages: English as an attachment in your email.

The manual is 1,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info