635921
2
Zoom out
Zoom in
Previous page
1/2
Next page
Operating Instructions - ET15
Click www.andrews-sykes.com or Call Us Free 0800 211 611
Operation Instructions
The control panel on the room unit is illustrated above
Revolve thermostat knob fully CLOCKWISE to the number ‘8’ position
Plug in the room unit mains cable, and switch on the electricity, red mains
light will illuminate.
Select ‘Fan Only’ with the mode switch. The fan will start.
Select ‘Fan Speed’ with the fan speed switch, high or low depending on air
velocity required.
Select ‘Cooling’ with the mode switch, and revolve the thermostat knob fully
ANTI-CLOCKWISE to he number ‘1’ position. After a delay of 10 mins the
green ‘Cooling’ light will illuminate and the machine will proceed to cool the air.
Monitor the room temperature and when it has reduced to the desired level, very
slowly revolve the thermostat knob back, clockwise until the green ‘Cooling’
light goes out. The room unit will now control the room temperature cooling
automatically at this setting.
Routine Maintenance
The airlter must be kept clean, never allow to become choked with dust or dirt. If
allowed to do so, the performance of the unit will become impaired, resulting in loss of
air flow, freezing up the evaporator coil and possible component damage.
Accessing the Filter
On machines fitted with a hinged lower panel, open panel. The filter is located on
front of the evaporator. A second filter is fitted to the rear panel on all air cooled
machines (fig. 5 & 6).
The filter can be washed in warm, soapy water, rinsed and shaken dry before
replacement. Frequency of cleaning depends upon application and can only be
determined by the user. However, you should never allow more than two months
to elapse between cleaning. The probable life of thelter will be about one year
and spares are available from the supplier of the unit itself. Failure to havelter fitted
during operation will cause serious damage.
Problem Likely Cause Solution
No cooling Amber ‘ATTENTION’ light
illuminated. High level
condensate trip.
Condensate pump not reducing water level.
Kink in condensate tube between room unit
and external heat exchanger?
Leak inside room unit. Pumplter inside
room unit blocked. Condensate tube frozen.
No cooling Amber ‘ATTENTION’ light
illuminated. Bottle fitted
switch trip.
ensure bottle fitted correctly.
No cooling Amber ‘CONTAINER FULL
light illuminated. High level
condensate trip.
On machines without a removable
bottle, as above. On machines with a
bottle, remove container and replace
correctly.
To empty the condensate bottle:
Unscrew the 2 x thumb screws on the
front panel (fig. 2).
The front cover will hinge forward, giving
access to the container (fig. 3).
Empty the container, and carefully
replace (fig 4).
Ensure the drain pipe is fitted into the
container.
Fig. 5 - The filter is located on the rear of the unit, ensure it is kept clean.
Fig. 6 - And in the top of the hinged section, in front of the evaporator.
Fig.2
Fig.1
Fig.3 Fig.4
Fig.6
Fig.5
Fitting the hot air exhaust
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Andrews ET15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Andrews ET15 in the language / languages: English as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info