792117
14
Zoom out
Zoom in
Previous page
1/16
Next page
7.6 TRUNK VOLTAGE
User`s Manual
19 / 25
7.4
T
ILT
This menu shows tilt of three channels` power level.
C16,C17, C18: The channel number. Press [/] to switch between them. Press
[/] to change the channel number and press [OK] to pop out
the channel list to select.
FREQ: The frequency of each channel
LEVEL: The power level of the first channel
DELTA1: The delta of power level to the first channel
DELTA2: The delta of power level to the first channel
7.5
S
PECTRUM
C
HART
This menu shows the spectrum chart of the setting
frequency range. Please see below screenshot.
Press [/] to switch between current frequency, start
frequency and end frequency:
Press [/] to change start or end frequency of the
spectrum frequency range if the curse is focusing on the
start or end frequency icon.
40~50~60: The range of the level value. Press [F3] to switch range between 40~60,
40~80 and 40~100.
C6/175MHz/0 dBuV: The curse of the current frequency and power level. Press [/]
to change the value.
162: The start frequency of the spectrum chart.
498: The end frequency of the spectrum chart.
7.6
T
RUNK
V
OLTAGE
This menu measures the trunk voltage. Press [OK] to switch
alternating current and direct current.
8. ANALOGUE TV
User`s Manual
20 / 25
8.
A
NALOGUE
TV
User can measure analogue TV signal in this submenu.
There are total three submenus: Measure, Tilt and Spectrum
chart.
8.1
M
EASURE
User can read SNR, Video and audio ratio, level, strength and
quality of the analogue TV signal in this menu.
: The lock status. The signal is locking if the icon is green otherwise the
color of the icon is red.
A: The frequency channel name.
FREQ: The current frequency. Press [/] to change the value or press [OK] to
edit it.
SYS: The analogue TV system mode. The value system will be get automatically
once the signal locks.
SNR: The signal noise rate value of the live signal.
V/A: The video and audio ratio of signal.
LEVEL: The power level value of the live signal.
Str: The strength value of the connected signal.
Q l t : The quality value of the connected signal.
8.2
TILT
Please refer to 7.4
8.3
S
PECTRUM
Please refer to 7.5
8.1 MEASURE
User can read SNR, Video and audio ratio, level, strength and quality of the analogue TV signal in this menu.
User`s Manual
20 / 25
8.
A
NALOGUE
TV
User can measure analogue TV signal in this submenu.
There are total three submenus: Measure, Tilt and Spectrum
chart.
8.1
M
EASURE
User can read SNR, Video and audio ratio, level, strength and
quality of the analogue TV signal in this menu.
: The lock status. The signal is locking if the icon is green otherwise the
color of the icon is red.
A: The frequency channel name.
FREQ: The current frequency. Press [/] to change the value or press [OK] to
edit it.
SYS: The analogue TV system mode. The value system will be get automatically
once the signal locks.
SNR: The signal noise rate value of the live signal.
V/A: The video and audio ratio of signal.
LEVEL: The power level value of the live signal.
Str: The strength value of the connected signal.
Q l t : The quality value of the connected signal.
8.2
TILT
Please refer to 7.4
8.3
S
PECTRUM
Please refer to 7.5
V/A: The video and audio ratio of signal.
LEVEL: The power level value of the live signal.
Str: The strength value of the connected signal.
Qlt: The quality value of the connected signal.
8.2 TILT
Please refer to 7.4
8.3 SPECTRUM
Please refer to 7.5
9. SYSTEM SETTING
User`s Manual
21 / 25
9.
S
YSTEM
S
ETTING
Beep: The beep status during pressing keys or when the signal is locking.
Press [/] to turn on or turn off beep.
Auto Standby: Set the time for meter to enter standby mode automatically. Press
[/] to switch between Off, 10 min, 20 min, 30 min and 60 min.
Language: The language of UI. Press [/] to switch between available
languages
Factory Reset: Press [OK] to display a confirm dialog. Then select YES to do a
factory reset or select NO to cancel.
Hardware Ver: The version number of hardware.
Software Ver: The version number of software.
10.
A
CCESSORIES
Power adapter, 2 RF connector, 1 CD for user manual, Carry bag, Car charger.
11.
T
ROUBLE SHOOTING
1. Unable to power on: Charge the meter about 3 hours until the charge light turn blue.
2. Warning LED flashing: Antenna overload, power off the meter and check the signal cable.
After that please power on again.
3. Hung up: Press the reset button to reset the meter.
4. Cant lock signal: Please confirm the signal cable is connected correctly and make
sure the antenna power is been set to ON if the antenna needs
power supply.
5. Other questions: please contact your dealer
Factory Reset:
Press [OK] to display a confirm dialog. Then select YES to do a factory reset or select NO to cancel.
Hardware Ver: The version number of hardware.
Software Ver: The version number of software.
10. ACCESSORIES
Power adapter, 2 RF connector, 1 CD for user manual, Carry bag, Car charger.
14
User`s Manual
16 / 25
6.
DVBT/T2/ISDBT
User can measure the live DVB-T/T2 signal, analyze the
spectrum, the scope between transponders , auto scan all
the saved frequencies and list all the locked ones. There
are six submenus: Measure, Auto Scan, RF Channel List ,
Scope, Spectrum chart and ANT power.
6.
1
T
ERRESTRIAL
M
EASURE
The device will show SNR, CBER, VBER, power value,
strength and quality of the connected live signal. Please see
below for detail.
: The lock status. The signal is locking if the icon is green otherwise the
color of the icon is red.
C12: The channel name.
5V, 12V,18V: The antenna output voltage. The color of icon will be green once the voltage
is outputting or the color is gray.
DVB T2: The terrestrial system. The values are DVB T and DVB T2. Press [/]
to switch them.
FREQ: The current frequency. Press [/] to change the frequency or [OK]
to edit it.
BW: The bandwidth of the live signal. Press [/] to switch between 6M,
7M and 8M.
SNR: The signal noise rate value of the live signal.
CBER: The CBER(BER before FEC) value of the live signal.
LBER: The LBER(BER after LDPC) value of the live signal.
LEVEL: The power level value of the live signal.
Str: The strength of the live signal in percent.
Qlt: The quality of the live signal in percent.
: The lock status. The signal is locking if the icon is green otherwise
the color of the icon is red.
A: The frequency channel name.
FREQ: The current frequency. Press
/
to change the value or press
[OK] to edit it.
SYS: The analogue TV system mode. The value system will be get auto-
matically once the signal locks.
SNR: The signal noise rate value of the live signal.
User can measure analogue TV signal in this submenu. There are total three
submenus: Measure, Tilt and Spectrum chart.
This menu measures the trunk voltage. Press [OK] to switch alternating
current and direct current.
Beep: The beep status during pressing keys or when the signal
is locking. Press
/
to turn on or turn off beep.
Auto Standby:
Set the time for meter to enter standby mode automati-
cally. Press / to switch between
Off, 10 min, 20 min,
30 min and 60 min.
Language: The language of UI. Press
/
to switch between
available languages.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Amiko TSC-1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Amiko TSC-1000 in the language / languages: English as an attachment in your email.

The manual is 2.37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info